Fully reconstructed t over(t, ̄) → W+ b W- over(b, ̄) → ℓ ν q over(q, ̄)′ b over(b, ̄) events are used to determine the fractions of right-handed (f+) and longitudinally polarized (f0) W bosons produced in top-quark decays. The helicity fractions are sensitive to the couplings and the Dirac structure of the Wtb vertex. This Letter reports measurements of the W-boson helicity fractions from two different methods using data corresponding to an integrated luminosity of 1.9 fb- 1 of p over(p, ̄) collisions at a center-of-mass energy of 1.96 TeV collected by the CDF II detector operating at the Fermilab Tevatron. Combining the results from the two methods, we find f0 = 0.62 ± 0.10 (stat) ± 0.05 (syst) under the assumption that f+ = 0, and f+ = - 0.04 ± 0.04 (stat) ± 0.03 (syst) with f0 fixed to the theoretically expected value of 0.70. Model-independent fits are also performed and simultaneously determine f0 = 0.66 ± 0.16 (stat) ± 0.05 (syst) and f+ = - 0.03 ± 0.06 (stat) ± 0.03 (syst). All these results are consistent with standard model expectations. © 2009 Elsevier B.V.

Measurement of W-boson helicity fractions in top-quark decays using cos θ*

Sforza F.;
2009-01-01

Abstract

Fully reconstructed t over(t, ̄) → W+ b W- over(b, ̄) → ℓ ν q over(q, ̄)′ b over(b, ̄) events are used to determine the fractions of right-handed (f+) and longitudinally polarized (f0) W bosons produced in top-quark decays. The helicity fractions are sensitive to the couplings and the Dirac structure of the Wtb vertex. This Letter reports measurements of the W-boson helicity fractions from two different methods using data corresponding to an integrated luminosity of 1.9 fb- 1 of p over(p, ̄) collisions at a center-of-mass energy of 1.96 TeV collected by the CDF II detector operating at the Fermilab Tevatron. Combining the results from the two methods, we find f0 = 0.62 ± 0.10 (stat) ± 0.05 (syst) under the assumption that f+ = 0, and f+ = - 0.04 ± 0.04 (stat) ± 0.03 (syst) with f0 fixed to the theoretically expected value of 0.70. Model-independent fits are also performed and simultaneously determine f0 = 0.66 ± 0.16 (stat) ± 0.05 (syst) and f+ = - 0.03 ± 0.06 (stat) ± 0.03 (syst). All these results are consistent with standard model expectations. © 2009 Elsevier B.V.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/964130
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 21
  • ???jsp.display-item.citation.isi??? 14
social impact