Aims: The aim of this study was to assess the feasibility of unprotected non-ostial left main (LM) imaging by frequency domain optical coherence tomography (FD-OCT). Methods and results: We conducted a retrospective analysis of OCT studies performed to image lesions located in the non-ostial LM. OCT studies were analysed to detect the number of artefact frames in the different LM/bifurcation segments. OCT cross-sectional images were used to assess area measures. OCT longitudinal reconstructions were used to obtain the LM length. Standard quantitative coronary angiography (QCA) was used as the reference methodology. A total of 54 patients with non-ostial LM disease entered the study. The mean number of LM artefact frames was 8 +/- 10, corresponding to 19% of the total number of LM frames analysed. The percentages of artefact frames differed significantly according to the segment analysed: 43.3% proximal LM, 11.4% mid LM and 2.1% distal LM, 1.9% ostial left anterior descending artery and 0% ostial left circumflex artery (p<0.0001). All LM OCT measurements were significantly correlated with QCA measurements. Conclusions: The results of the present study show that FD-OCT assessment of non-ostial LM disease is feasible and may provide high-quality imaging. OCT assessment of the distal LM is more efficient than that of the proximal LM segment.

Frequency domain optical coherence tomography to assess non-ostial left main coronary artery

Porto I;
2015-01-01

Abstract

Aims: The aim of this study was to assess the feasibility of unprotected non-ostial left main (LM) imaging by frequency domain optical coherence tomography (FD-OCT). Methods and results: We conducted a retrospective analysis of OCT studies performed to image lesions located in the non-ostial LM. OCT studies were analysed to detect the number of artefact frames in the different LM/bifurcation segments. OCT cross-sectional images were used to assess area measures. OCT longitudinal reconstructions were used to obtain the LM length. Standard quantitative coronary angiography (QCA) was used as the reference methodology. A total of 54 patients with non-ostial LM disease entered the study. The mean number of LM artefact frames was 8 +/- 10, corresponding to 19% of the total number of LM frames analysed. The percentages of artefact frames differed significantly according to the segment analysed: 43.3% proximal LM, 11.4% mid LM and 2.1% distal LM, 1.9% ostial left anterior descending artery and 0% ostial left circumflex artery (p<0.0001). All LM OCT measurements were significantly correlated with QCA measurements. Conclusions: The results of the present study show that FD-OCT assessment of non-ostial LM disease is feasible and may provide high-quality imaging. OCT assessment of the distal LM is more efficient than that of the proximal LM segment.
File in questo prodotto:
File Dimensione Formato  
frequency-domain-optical-coherence-tomography-to-assess-non-ostial-left-main-cor.pdf

accesso chiuso

Tipologia: Documento in versione editoriale
Dimensione 1.07 MB
Formato Adobe PDF
1.07 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/936596
Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 46
  • ???jsp.display-item.citation.isi??? 41
social impact