Background: Increased risk of breast cancer (BC) and increased risk of an interval BC at mammography screening are associated with high mammographic density. Adjunct imaging detects additional BCs not detected at mammography screening in women with dense breasts. Aim: The aim is to estimate the incremental cancer detection rate (CDR) and false-positive recall for each of tomosynthesis and ultrasound, as adjunct screening modalities in women with mammography-negative dense breasts. Methods: A multicentre prospective comparative trial of adjunct screening with tomosynthesis or ultrasound in women with mammography-negative dense breasts (ASTOUND-2) recruited asymptomatic women attending Italian breast screening services. All participants had independently interpreted tomosynthesis and ultrasound. Outcomes were ascertained from excision histopathology or completed assessment. Paired binary data were compared using McNemar's test. Results: We recruited 5300 screening participants with median age of 50 (interquartile range 43–79) years who had negative mammography and dense breasts (April 2015–September 2017). Adjunct screening detected 29 additional BCs (27 invasive, 2 in situ): 12 detected on both tomosynthesis and ultrasound, 3 detected only on tomosynthesis, 14 detected only on ultrasound. Incremental CDR for tomosynthesis (+15 cancers) was 2.83/1000 screens (95% confidence interval [CI]: 1.58–4.67) versus ultrasound (+26 cancers) with an incremental CDR of 4.90/1000 screens (95% CI: 3.21–7.19), P = 0.015. Mean size of these cancers was 14.2 mm (standard deviation: 7.8 mm), and six had nodal metastases. Incremental false-positive recall was 1.22% (95% CI: 0.91%–1.49%) and differed significantly between tomosynthesis (0.30%) and ultrasound (1.0%), P < 0.001. Conclusions: Ultrasound detected more BCs but caused more false positives than tomosynthesis, underscoring trade-offs in screening outcomes when adjunct imaging is used for screening dense breasts.

A prospective comparative trial of adjunct screening with tomosynthesis or ultrasound in women with mammography-negative dense breasts (ASTOUND-2)

Tagliafico, A. S.;Valdora, F;Sormani, M. P.;Signori, A.;
2018-01-01

Abstract

Background: Increased risk of breast cancer (BC) and increased risk of an interval BC at mammography screening are associated with high mammographic density. Adjunct imaging detects additional BCs not detected at mammography screening in women with dense breasts. Aim: The aim is to estimate the incremental cancer detection rate (CDR) and false-positive recall for each of tomosynthesis and ultrasound, as adjunct screening modalities in women with mammography-negative dense breasts. Methods: A multicentre prospective comparative trial of adjunct screening with tomosynthesis or ultrasound in women with mammography-negative dense breasts (ASTOUND-2) recruited asymptomatic women attending Italian breast screening services. All participants had independently interpreted tomosynthesis and ultrasound. Outcomes were ascertained from excision histopathology or completed assessment. Paired binary data were compared using McNemar's test. Results: We recruited 5300 screening participants with median age of 50 (interquartile range 43–79) years who had negative mammography and dense breasts (April 2015–September 2017). Adjunct screening detected 29 additional BCs (27 invasive, 2 in situ): 12 detected on both tomosynthesis and ultrasound, 3 detected only on tomosynthesis, 14 detected only on ultrasound. Incremental CDR for tomosynthesis (+15 cancers) was 2.83/1000 screens (95% confidence interval [CI]: 1.58–4.67) versus ultrasound (+26 cancers) with an incremental CDR of 4.90/1000 screens (95% CI: 3.21–7.19), P = 0.015. Mean size of these cancers was 14.2 mm (standard deviation: 7.8 mm), and six had nodal metastases. Incremental false-positive recall was 1.22% (95% CI: 0.91%–1.49%) and differed significantly between tomosynthesis (0.30%) and ultrasound (1.0%), P < 0.001. Conclusions: Ultrasound detected more BCs but caused more false positives than tomosynthesis, underscoring trade-offs in screening outcomes when adjunct imaging is used for screening dense breasts.
File in questo prodotto:
File Dimensione Formato  
Tagliafico_EJC_Astound2.pdf

accesso chiuso

Tipologia: Documento in versione editoriale
Dimensione 400.52 kB
Formato Adobe PDF
400.52 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/928432
Citazioni
  • ???jsp.display-item.citation.pmc??? 25
  • Scopus 90
  • ???jsp.display-item.citation.isi??? 89
social impact