PURPOSE: The aim of this study was to compare the success rate and safety of short-axis versus long-axis approaches to ultrasound-guided subclavian vein cannulation. METHODS: A total of 190 patients requiring central venous cannulation following cardiac surgery were randomized to either short-axis or long-axis ultrasound-guided cannulation of the subclavian vein. Each cannulation was performed by anesthesiologists with at least 3 years' experience of ultrasound-guided central vein cannulation (>150 procedures/year, 50% short-axis and 50% long-axis). Success rate, insertion time, number of needle redirections, number of separate skin or vessel punctures, rate of mechanical complications, catheter misplacements, and incidence of central line-associated bloodstream infection were documented for each procedure. RESULTS: The subclavian vein was successfully cannulated in all 190 patients. The mean insertion time was significantly shorter (p = 0.040) in the short-axis group (69 ± 74 s) than in the long-axis group (98 ± 103 s). The short-axis group was also associated with a higher overall success rate (96 vs. 78%, p < 0.001), first-puncture success rate (86 vs. 67%, p = 0.003), and first-puncture single-pass success rate (72 vs. 48%, p = 0.002), and with fewer needle redirections (0.39 ± 0.88 vs. 0.88 ± 1.15, p = 0.001), skin punctures (1.12 ± 0.38 vs. 1.28 ± 0.54, p = 0.019), and complications (3 vs. 13%, p = 0.028). CONCLUSIONS: The short-axis procedure for ultrasound-guided subclavian cannulation offers advantages over the long-axis approach in cardiac surgery patients.

A randomized clinical trial of ultrasound-guided infra-clavicular cannulation of the subclavian vein in cardiac surgical patients: short-axis versus long-axis approach

SANTORI, GREGORIO;
2017-01-01

Abstract

PURPOSE: The aim of this study was to compare the success rate and safety of short-axis versus long-axis approaches to ultrasound-guided subclavian vein cannulation. METHODS: A total of 190 patients requiring central venous cannulation following cardiac surgery were randomized to either short-axis or long-axis ultrasound-guided cannulation of the subclavian vein. Each cannulation was performed by anesthesiologists with at least 3 years' experience of ultrasound-guided central vein cannulation (>150 procedures/year, 50% short-axis and 50% long-axis). Success rate, insertion time, number of needle redirections, number of separate skin or vessel punctures, rate of mechanical complications, catheter misplacements, and incidence of central line-associated bloodstream infection were documented for each procedure. RESULTS: The subclavian vein was successfully cannulated in all 190 patients. The mean insertion time was significantly shorter (p = 0.040) in the short-axis group (69 ± 74 s) than in the long-axis group (98 ± 103 s). The short-axis group was also associated with a higher overall success rate (96 vs. 78%, p < 0.001), first-puncture success rate (86 vs. 67%, p = 0.003), and first-puncture single-pass success rate (72 vs. 48%, p = 0.002), and with fewer needle redirections (0.39 ± 0.88 vs. 0.88 ± 1.15, p = 0.001), skin punctures (1.12 ± 0.38 vs. 1.28 ± 0.54, p = 0.019), and complications (3 vs. 13%, p = 0.028). CONCLUSIONS: The short-axis procedure for ultrasound-guided subclavian cannulation offers advantages over the long-axis approach in cardiac surgery patients.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/882944
Citazioni
  • ???jsp.display-item.citation.pmc??? 14
  • Scopus 39
  • ???jsp.display-item.citation.isi??? 31
social impact