Background: In multiple sclerosis (MS), recent work suggests that cervical cord atrophy is more consistently correlated with physical disability than brain white matter lesion load and atrophy. Although spinal cord imaging has not been routinely obtained in many clinical trial and research studies, brain volumetric imaging usually has and includes the upper cervical cord. Objectives: Using volumetric T1-weighted brain images, we investigated cross-sectional area measures in the uppermost cervical cord and compared them with areas at the standard C2/ 3 level. Methods: Using T1-weighted brain scans from 13 controls and 37 people with MS, and an active surface technique, cross-sectional area was measured over 5 mm and 1 mm cord segments at C2/3, below the level of odontoid peg, and 2 cm and 2.5 cm below the pons. Brain volume was also measured. Results: Cord area measurements were most reliable in a 5 mm segment 2.5 cm below the pons (inter-rater coefficient of variation 1.5%, intraclass correlation coefficient 0.99). Cord area at this level correlated more with that at C2/3 area than with brain volume (r=0.811 with C2/3, r=0.502 with brain volume).

Cervical cord area measurement using volumetric brain magnetic resonance imaging in multiple sclerosis

PARDINI, MATTEO;
2015-01-01

Abstract

Background: In multiple sclerosis (MS), recent work suggests that cervical cord atrophy is more consistently correlated with physical disability than brain white matter lesion load and atrophy. Although spinal cord imaging has not been routinely obtained in many clinical trial and research studies, brain volumetric imaging usually has and includes the upper cervical cord. Objectives: Using volumetric T1-weighted brain images, we investigated cross-sectional area measures in the uppermost cervical cord and compared them with areas at the standard C2/ 3 level. Methods: Using T1-weighted brain scans from 13 controls and 37 people with MS, and an active surface technique, cross-sectional area was measured over 5 mm and 1 mm cord segments at C2/3, below the level of odontoid peg, and 2 cm and 2.5 cm below the pons. Brain volume was also measured. Results: Cord area measurements were most reliable in a 5 mm segment 2.5 cm below the pons (inter-rater coefficient of variation 1.5%, intraclass correlation coefficient 0.99). Cord area at this level correlated more with that at C2/3 area than with brain volume (r=0.811 with C2/3, r=0.502 with brain volume).
File in questo prodotto:
File Dimensione Formato  
Cervical cord area measurement using 2015.pdf

accesso chiuso

Tipologia: Documento in versione editoriale
Dimensione 630.16 kB
Formato Adobe PDF
630.16 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/780213
Citazioni
  • ???jsp.display-item.citation.pmc??? 13
  • Scopus 27
  • ???jsp.display-item.citation.isi??? 26
social impact