AIM: The aim of this study is to validate the accuracy of HER2 assessment on biopsies by comparing matched biopsy/surgical material from the same patients. METHODS: HER2 status was evaluated by immunohistochemistry (IHC) and fluorescence in situ hybridization (FISH) in 103 cases of gastric and gastroesophageal junction cancers in coupled biopsy and surgical material. RESULT: Complete concordance between IHC and FISH results on biopsy versus surgical samples was noted in 80% and 95% of cases, respectively. At comprehensive comparison, including IHC and FISH data on biopsy and surgical samples, 89% of biopsies were predictive of HER2 status in surgical samples, whereas 11% showed variable inconsistencies. The majority of these (10 of 12 cases) showed IHC score 0/1+ on biopsy but were all IHC positive and amplified at surgery; in particular, three (3 of 35; 8.5%) IHC score 0 and four (4 of 16; 25%) IHC score 1+ cases were FISH amplified on biopsy material also, whereas the remaining three cases were FISH non-amplified on biopsy. The percentage of cases, which were FISH amplified with IHC score 1+ or 2+ on biopsies, were similar (25% and 33%, respectively) and they also shared a similar grade of amplification. These data suggest that both IHC score 1+ and 2+ on biopsy material represent "equivocal cases" that may merit further investigation. CONCLUSIONS: The predictive value of HER2 IHC in biopsies is high. FISH analysis should be considered for IHC score 2+ and 1+ biopsy cases. Approximately 8% of cases will not be accurately predicted by biopsy evaluation.

The reliability of endoscopic biopsies in assessing HER2 status in gastric and gastroesophageal junction cancer: A study comparing biopsies with surgical samples

GRILLO, FEDERICA;CURTO, MONICA;FIOCCA, ROBERTO;MASTRACCI, LUCA
2013-01-01

Abstract

AIM: The aim of this study is to validate the accuracy of HER2 assessment on biopsies by comparing matched biopsy/surgical material from the same patients. METHODS: HER2 status was evaluated by immunohistochemistry (IHC) and fluorescence in situ hybridization (FISH) in 103 cases of gastric and gastroesophageal junction cancers in coupled biopsy and surgical material. RESULT: Complete concordance between IHC and FISH results on biopsy versus surgical samples was noted in 80% and 95% of cases, respectively. At comprehensive comparison, including IHC and FISH data on biopsy and surgical samples, 89% of biopsies were predictive of HER2 status in surgical samples, whereas 11% showed variable inconsistencies. The majority of these (10 of 12 cases) showed IHC score 0/1+ on biopsy but were all IHC positive and amplified at surgery; in particular, three (3 of 35; 8.5%) IHC score 0 and four (4 of 16; 25%) IHC score 1+ cases were FISH amplified on biopsy material also, whereas the remaining three cases were FISH non-amplified on biopsy. The percentage of cases, which were FISH amplified with IHC score 1+ or 2+ on biopsies, were similar (25% and 33%, respectively) and they also shared a similar grade of amplification. These data suggest that both IHC score 1+ and 2+ on biopsy material represent "equivocal cases" that may merit further investigation. CONCLUSIONS: The predictive value of HER2 IHC in biopsies is high. FISH analysis should be considered for IHC score 2+ and 1+ biopsy cases. Approximately 8% of cases will not be accurately predicted by biopsy evaluation.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/747802
Citazioni
  • ???jsp.display-item.citation.pmc??? 12