A small set of final prototypes of the ATLAS Inner Detector silicon tracking system
(Pixel Detector and SemiConductor Tracker), were used to take data during the 2004 Combined
Test Beam. Data were collected from runs with beams of different flavour (electrons, pions, muons
and photons) with a momentum range of 2 to 180 GeV/c. Four independent methods were used
to align the silicon modules. The corrections obtained were validated using the known momenta
of the beam particles and were shown to yield consistent results among the different alignment
approaches. From the residual distributions, it is concluded that the precision attained in the alignment
of the silicon modules is of the order of 5 micron in their most precise coordinate.
Alignment of the Pixel and SCT Modules for the 2004 ATLAS Combined Test Beam
A. Ahmad;A. Andreazza;T. Atkinson;J. Baines;A. J. Barr;R. Beccherle;P. J. Bell;J. Bernabeu;Z. Broklova;P. A. Bruckman de Renstrom;D. Cauz;L. Chevalier;S. Chouridou;M. Citterio;A. Clark;M. Cobal;T. Cornelissen;S. Correard;M. J. Costa;D. Costanzo;S. Cuneo;M. Dameri;G. Darbo;J. B. de Vivie;B. Di Girolamo;D. Dobos;Z. Drasal;J. Drohan;K. Einsweiler;M. Elsing;D. Emelyanov;C. Escobar;K. Facius;P. Ferrari;D. Fergusson;D. Ferrere;T. Flick;D. Froidevaux;GAGLIARDI, GUIDO;M. Gallas;B. J. Gallop;K. K. Gan;C. Garcia;I. L. Gavrilenko;C. Gemme;P. Gerlach;T. Golling;S. Gonzalez Sevilla;M. J. Goodrick;G. Gorfine;T. Göttfert;J. Grosse Knetter;P. H. Hansen;K. Hara;R. Härtel;A. Harvey;R. J. Hawkings;F. E. W. Heinemann;T. Henss;J. C. Hill;F. Huegging;E. Jansen;J. Joseph;M. Karagöz Ünel;M. Kataoka;S. Kersten;A. Khomich;R. Klingenberg;P. Kodys;T. Koffas;N. Konstantinidis;V. Kostyukhin;C. Lacasta;T. Lari;S. Latorre;C. G. Lester;W. Liebig;A. Lipniacka;K. F. Lourerio;M. Mangin Brinet;S. Marti i. Garcia;M. Mathes;C. Meroni;B. Mikulec;B. Mindur;S. Moed;G. Moorhead;P. Morettini;E. W. J. Moyse;K. Nakamura;P. Nechaeva;K. Nikolaev;PARODI, FABRIZIO;S. Parzhitskiy;J. Pater;R. Petti;P. W. Phillips;B. Pinto;A. Poppleton;K. Reeves;I. Reisinger;P. Reznicek;P. Risso;D. Robinson;S. Roe;A. Rozanov;A. Salzburger;H. Sandaker;L. Santi;SCHIAVI, CARLO;J. Schieck;J. Schultes;A. Sfyrla;C. Shaw;F. Tegenfeldt;C. J. W. P. Timmermans;B. Toczek;C. Troncon;M. Tyndel;F. Vernocchi;J. Virzi;T. Vu Anh;M. Warren;J. Weber;M. Weber;A. R. Weidberg;J. Weingarten;P. S. Wells;A. Zhelezko
2008
Abstract
A small set of final prototypes of the ATLAS Inner Detector silicon tracking system
(Pixel Detector and SemiConductor Tracker), were used to take data during the 2004 Combined
Test Beam. Data were collected from runs with beams of different flavour (electrons, pions, muons
and photons) with a momentum range of 2 to 180 GeV/c. Four independent methods were used
to align the silicon modules. The corrections obtained were validated using the known momenta
of the beam particles and were shown to yield consistent results among the different alignment
approaches. From the residual distributions, it is concluded that the precision attained in the alignment
of the silicon modules is of the order of 5 micron in their most precise coordinate.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: http://hdl.handle.net/11567/536318
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo
Citazioni
ND
5
4
social impact
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2021-2023 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.