OBJECTIVES: The aim of the study was to assess the extent of the potential nerve damage following prolonged contact with a piezoelectric device. METHODS: The study was conducted with 30 patients; all of the patients had cervical metastatic lymph nodes at levels II, III, and IV (N2b) and a negative evaluation for metastatic disease (MO). The patients underwent radical neck dissection. After its skeletonization, the spinal nerve was exposed directly to ultrasonic activation with a piezoelectric device for various times (5, 10, and 20 seconds) and with different inserts (OP3 insert and OT7 insert). The axonal damage was graded from 0 to 3 as follows: 0, no damage; 1, minor axonal damage; 2, severe axonal damage but not covering the entirety of the nerve fascicles; 3, severe axonal damage covering the entirety of the nerve fascicles. RESULTS: Histologic examination showed no evidence of damage to the perineurium and axons after 5 and 10 seconds of exposure to ultrasonic activation with each insert. CONCLUSIONS: Our histologic data highlight the selective action of the piezoelectric device, which reduces the risk of accidental nerve damage in otolaryngological bone surgery.

Potential nerve damage following contact with a piezoelectric device

GUASTINI, LUCA
2011-01-01

Abstract

OBJECTIVES: The aim of the study was to assess the extent of the potential nerve damage following prolonged contact with a piezoelectric device. METHODS: The study was conducted with 30 patients; all of the patients had cervical metastatic lymph nodes at levels II, III, and IV (N2b) and a negative evaluation for metastatic disease (MO). The patients underwent radical neck dissection. After its skeletonization, the spinal nerve was exposed directly to ultrasonic activation with a piezoelectric device for various times (5, 10, and 20 seconds) and with different inserts (OP3 insert and OT7 insert). The axonal damage was graded from 0 to 3 as follows: 0, no damage; 1, minor axonal damage; 2, severe axonal damage but not covering the entirety of the nerve fascicles; 3, severe axonal damage covering the entirety of the nerve fascicles. RESULTS: Histologic examination showed no evidence of damage to the perineurium and axons after 5 and 10 seconds of exposure to ultrasonic activation with each insert. CONCLUSIONS: Our histologic data highlight the selective action of the piezoelectric device, which reduces the risk of accidental nerve damage in otolaryngological bone surgery.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/331270
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact