A new control strategy has been developed for interfacing a neutral-point-clamped active rectifier with the mains. In particular, a method, based on the modulation of the input currents amplitudes, is proposed to compensate the dc-link capacitors voltages fluctuations. The proposed strategy gives good results in all the operating conditions, but it appears to be very useful especially in no-load or low-load operations, where other methods fail. Analytical, simulation, and experimental results, derived from a reduced-scale prototype, are presented and confirm the validity of the proposed approach.
A new control strategy for Neutral-Point-Clamped active rectifiers
MARCHESONI, MARIO;
2005-01-01
Abstract
A new control strategy has been developed for interfacing a neutral-point-clamped active rectifier with the mains. In particular, a method, based on the modulation of the input currents amplitudes, is proposed to compensate the dc-link capacitors voltages fluctuations. The proposed strategy gives good results in all the operating conditions, but it appears to be very useful especially in no-load or low-load operations, where other methods fail. Analytical, simulation, and experimental results, derived from a reduced-scale prototype, are presented and confirm the validity of the proposed approach.File in questo prodotto: