The aim of this study was to identify a method for staging hepatic fibrosis using a non-invasive, rapid and inexpensive technique based on ultrasound morphologic hepatic features. A total of 215 patients with different liver diseases underwent B-mode (2-D brightness mode) ultrasonography, vibration-controlled transient elastography, 2-D shear wave elastography and measurement of the controlled attenuation parameter with transient elastography. B-Mode images of the anterior margin of the left lobe were obtained and processed with automatic Genoa Line Quantification (GLQ) software based on a neural network for staging liver fibrosis. The accuracy of GLQ was 90.6% during model training and 78.9% in 38 different patients with concordant elastometric measures. Receiver operating characteristic curve analysis of GLQ performance using vibration-controlled transient elastography as a reference yielded areas under the curves of 0.851 for F ≥ F1, 0.793 for F ≥ F2, 0.784 for F ≥ F3 and 0.789 for F ≥ F4. GLQ has the potential to be a rapid, easy-to-perform and tolerable method in the staging of liver fibrosis.
Hepatic Elastometry and Glissonian Line in the Assessment of Liver Fibrosis
Borro P.;Ziola S.;Pasta A.;Trombini M.;Labanca S.;Marenco S.;Solarna D.;Pisciotta L.;Baldissarro I.;Picciotto A.;Dellepiane S.
2021-01-01
Abstract
The aim of this study was to identify a method for staging hepatic fibrosis using a non-invasive, rapid and inexpensive technique based on ultrasound morphologic hepatic features. A total of 215 patients with different liver diseases underwent B-mode (2-D brightness mode) ultrasonography, vibration-controlled transient elastography, 2-D shear wave elastography and measurement of the controlled attenuation parameter with transient elastography. B-Mode images of the anterior margin of the left lobe were obtained and processed with automatic Genoa Line Quantification (GLQ) software based on a neural network for staging liver fibrosis. The accuracy of GLQ was 90.6% during model training and 78.9% in 38 different patients with concordant elastometric measures. Receiver operating characteristic curve analysis of GLQ performance using vibration-controlled transient elastography as a reference yielded areas under the curves of 0.851 for F ≥ F1, 0.793 for F ≥ F2, 0.784 for F ≥ F3 and 0.789 for F ≥ F4. GLQ has the potential to be a rapid, easy-to-perform and tolerable method in the staging of liver fibrosis.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.