To investigate the effects of proportional assist ventilation, variable pressure support, and conventional pressure support ventilation on lung function and damage in experimental acute lung injury. DESIGN: : Randomized experimental study. SETTING: University hospital research facility. SUBJECTS: : Twenty-four juvenile pigs. INTERVENTIONS: Pigs were anesthetized, intubated, and mechanically ventilated. Acute lung injury was induced by saline lung lavage. After resuming of spontaneous breathing, animals were randomly assigned to 6 hrs of assisted ventilation with pressure support ventilation, proportional assist ventilation, or variable pressure support (n = 8 per group). Mean tidal volume was kept at ≈6 mL/kg in all modes. MEASUREMENTS AND MAIN RESULTS: Lung functional parameters, distribution of ventilation by electrical impedance tomography, and breathing patterns were analyzed. Histological lung damage and pulmonary inflammatory response were determined postmortem. Variable -pressure support and proportional assist ventilation improved oxygenation and venous admixture compared with pressure support ventilation. Proportional assist ventilation led to higher esophageal pressure time product than variable pressure support and pressure support ventilation, and redistributed ventilation from central to dorsal lung regions compared to pressure support ventilation. Variable pressure support and proportional assist ventilation yielded higher tidal volume variability than pressure support ventilation. Such pattern was deterministic (self-organized) during proportional assist ventilation and stochastic (random) during variable pressure support. Subject-ventilator synchrony as well as pulmonary inflammatory response and damage did not differ among groups. CONCLUSIONS: In a lung lavage model of acute lung injury, both variable pressure support and proportional assist ventilation increased the variability of tidal volume and improved oxygenation and venous admixture, without influencing subject-ventilator synchrony or affecting lung injury compared with pressure support ventilation. However, variable pressure support yielded less inspiratory effort than proportional assist ventilation at comparable mean tidal volumes of 6 mL/kg.

Comparative effects of proportional assist and variable pressure support ventilation on lung function and damage in experimental lung injury*

Pelosi, P;
2012-01-01

Abstract

To investigate the effects of proportional assist ventilation, variable pressure support, and conventional pressure support ventilation on lung function and damage in experimental acute lung injury. DESIGN: : Randomized experimental study. SETTING: University hospital research facility. SUBJECTS: : Twenty-four juvenile pigs. INTERVENTIONS: Pigs were anesthetized, intubated, and mechanically ventilated. Acute lung injury was induced by saline lung lavage. After resuming of spontaneous breathing, animals were randomly assigned to 6 hrs of assisted ventilation with pressure support ventilation, proportional assist ventilation, or variable pressure support (n = 8 per group). Mean tidal volume was kept at ≈6 mL/kg in all modes. MEASUREMENTS AND MAIN RESULTS: Lung functional parameters, distribution of ventilation by electrical impedance tomography, and breathing patterns were analyzed. Histological lung damage and pulmonary inflammatory response were determined postmortem. Variable -pressure support and proportional assist ventilation improved oxygenation and venous admixture compared with pressure support ventilation. Proportional assist ventilation led to higher esophageal pressure time product than variable pressure support and pressure support ventilation, and redistributed ventilation from central to dorsal lung regions compared to pressure support ventilation. Variable pressure support and proportional assist ventilation yielded higher tidal volume variability than pressure support ventilation. Such pattern was deterministic (self-organized) during proportional assist ventilation and stochastic (random) during variable pressure support. Subject-ventilator synchrony as well as pulmonary inflammatory response and damage did not differ among groups. CONCLUSIONS: In a lung lavage model of acute lung injury, both variable pressure support and proportional assist ventilation increased the variability of tidal volume and improved oxygenation and venous admixture, without influencing subject-ventilator synchrony or affecting lung injury compared with pressure support ventilation. However, variable pressure support yielded less inspiratory effort than proportional assist ventilation at comparable mean tidal volumes of 6 mL/kg.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/656385
Citazioni
  • ???jsp.display-item.citation.pmc??? 19
  • Scopus 31
  • ???jsp.display-item.citation.isi??? 30
social impact