The pantograph voltage and current waveforms recorded across the Italian and French high speed railway lines (both Autotransformer 2x25 kV 50 Hz systems) are analyzed to estimate some Power Quality indexes: harmonic spectra, harmonic distortion, displacement factor and fundamental component, in various load conditions. These indexes, that define the electrical interface between the rolling stock and the power supply, are all required by the technical standards for interoperability

Results on the Power Quality of French and Italian 2x25 kV 50 Hz railways

MARISCOTTI, ANDREA
2012-01-01

Abstract

The pantograph voltage and current waveforms recorded across the Italian and French high speed railway lines (both Autotransformer 2x25 kV 50 Hz systems) are analyzed to estimate some Power Quality indexes: harmonic spectra, harmonic distortion, displacement factor and fundamental component, in various load conditions. These indexes, that define the electrical interface between the rolling stock and the power supply, are all required by the technical standards for interoperability
2012
9781457717710
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/630587
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 23
  • ???jsp.display-item.citation.isi??? 12
social impact