In this work the partial discharge (PD) patterns acquired during electrical aging tests performed on twisted pair specimens prepared by winding wires having conventional or nanostructured enamel insulation are compared. The conventional enamel is polyamide imide, while the nanostructured enamel is a polyamide-silica nanocomposite. The tests have been performed applying sinusoidal voltage at different frequencies. The outcome shows interesting features of the PD activity monitored during the tests allowing a comparison between the two different insulating systems.

Electrical ageing test on conventional and nanocomposite enamels: PD patterns analysis

COLETTI, GIANFRANCO;GUASTAVINO, FRANCESCO;TORELLO, EUGENIA
2009-01-01

Abstract

In this work the partial discharge (PD) patterns acquired during electrical aging tests performed on twisted pair specimens prepared by winding wires having conventional or nanostructured enamel insulation are compared. The conventional enamel is polyamide imide, while the nanostructured enamel is a polyamide-silica nanocomposite. The tests have been performed applying sinusoidal voltage at different frequencies. The outcome shows interesting features of the PD activity monitored during the tests allowing a comparison between the two different insulating systems.
2009
9781424439171
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/249887
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 0
social impact