The WMO Field Intercomparison of Rainfall Intensity (RI) Gauges started on October, 1st 2007 at Vigna di Valle (Italy) and was concluded in May 2009. Those catching type instruments, out of the selected rain gauges based on various measuring principles, and the four rain gauges selected as reference instruments to be installed in a pit, were preliminarily calibrated in the laboratory before their final installation at the Field Intercomparison site. The recognized WMO laboratory at the University of Genoa was involved in this task, using the same standard tests adopted for the previously held WMO Laboratory Intercomparison of RI gauges. Further tests were performed to investigate the one-minute performance of the involved instruments. The present paper deals with basically Tipping-Bucket Rain gauges (TBRs) and Weighing Gauges (WGs), using results from tests performed under constant flow rates in laboratory conditions. The objective of this initial phase of the Intercomparison was to single out the counting errors associated with each instrument, so as to help the understanding of the measured differences between instruments in the field during the second phase. Results and comments on the preliminary laboratory calibration exercise are reported in this paper together with their implications for the analysis of the outcome of the Intercomparison in the Field.

High resolution performance of catching type rain gauges from the laboratory phase of the WMO Field Intercomparison of Rain Intensity Gauges

LANZA, LUCA GIOVANNI;STAGI, LUIGI
2009-01-01

Abstract

The WMO Field Intercomparison of Rainfall Intensity (RI) Gauges started on October, 1st 2007 at Vigna di Valle (Italy) and was concluded in May 2009. Those catching type instruments, out of the selected rain gauges based on various measuring principles, and the four rain gauges selected as reference instruments to be installed in a pit, were preliminarily calibrated in the laboratory before their final installation at the Field Intercomparison site. The recognized WMO laboratory at the University of Genoa was involved in this task, using the same standard tests adopted for the previously held WMO Laboratory Intercomparison of RI gauges. Further tests were performed to investigate the one-minute performance of the involved instruments. The present paper deals with basically Tipping-Bucket Rain gauges (TBRs) and Weighing Gauges (WGs), using results from tests performed under constant flow rates in laboratory conditions. The objective of this initial phase of the Intercomparison was to single out the counting errors associated with each instrument, so as to help the understanding of the measured differences between instruments in the field during the second phase. Results and comments on the preliminary laboratory calibration exercise are reported in this paper together with their implications for the analysis of the outcome of the Intercomparison in the Field.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/219469
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 42
  • ???jsp.display-item.citation.isi??? 36
social impact