This paper presents the unsteady flow interactions between an engine-representative highpressure turbine (HPT) and low-pressure turbine (LPT) stage, connected by a turbine center frame (TCF) duct with nonturning struts. The setup was tested at the high-speed two-spool test turbine facility at the Institute for Thermal Turbomachinery and Machine Dynamics at Graz University of Technology and includes relevant purge and turbine rotor tip leakage flows. Due to the complexity of such a test, the unsteady component interactions in an HPT-TCF-LPT module have not received much attention in the past and require additional analysis to determine new approaches for further performance improvements on the system level. The flow downstream of an HPT is highly unsteady and dominated by stator-rotor interactions, which affect the flow behavior through the downstream TCF and LPT. To capture the unsteady flow structures, time-resolved aerodynamic measurements were carried out with a fast-response aerodynamic pressure probe (FRAPP) at three different measurement planes. In this paper, the time-resolved and phase-averaged flow fields with respect to the HPT and LPT trigger are studied. Since the two rotors are uncorrelated, the applied method allows the identification of the flow structures induced by either of them. Upstream of the LPT stage, the HPT flow structures evolving through the TCF duct dominate the flow fields. Downstream of the LPT stage, the flow is affected by both the HPT and the LPT secondary flow structures. The interactions between the various stator rows and the two rotors are detected by means of time-space plots and modal decomposition. To describe the fluctuations induced by both rotors, particularly the rotor-rotor interaction, the rotor synchronic averaging (RSA) is used to analyze the flow field downstream of the LPT. This paper highlights the need to account for the HPTinduced unsteady mechanisms in addition to the LPT flow structures and the interaction of both to arrive at improved LPT designs.

Unsteady flow interactions between a high- And low-pressure turbine

Dellacasagrande M.;
2020-01-01

Abstract

This paper presents the unsteady flow interactions between an engine-representative highpressure turbine (HPT) and low-pressure turbine (LPT) stage, connected by a turbine center frame (TCF) duct with nonturning struts. The setup was tested at the high-speed two-spool test turbine facility at the Institute for Thermal Turbomachinery and Machine Dynamics at Graz University of Technology and includes relevant purge and turbine rotor tip leakage flows. Due to the complexity of such a test, the unsteady component interactions in an HPT-TCF-LPT module have not received much attention in the past and require additional analysis to determine new approaches for further performance improvements on the system level. The flow downstream of an HPT is highly unsteady and dominated by stator-rotor interactions, which affect the flow behavior through the downstream TCF and LPT. To capture the unsteady flow structures, time-resolved aerodynamic measurements were carried out with a fast-response aerodynamic pressure probe (FRAPP) at three different measurement planes. In this paper, the time-resolved and phase-averaged flow fields with respect to the HPT and LPT trigger are studied. Since the two rotors are uncorrelated, the applied method allows the identification of the flow structures induced by either of them. Upstream of the LPT stage, the HPT flow structures evolving through the TCF duct dominate the flow fields. Downstream of the LPT stage, the flow is affected by both the HPT and the LPT secondary flow structures. The interactions between the various stator rows and the two rotors are detected by means of time-space plots and modal decomposition. To describe the fluctuations induced by both rotors, particularly the rotor-rotor interaction, the rotor synchronic averaging (RSA) is used to analyze the flow field downstream of the LPT. This paper highlights the need to account for the HPTinduced unsteady mechanisms in addition to the LPT flow structures and the interaction of both to arrive at improved LPT designs.
File in questo prodotto:
File Dimensione Formato  
turbo_142_10_101012.pdf

accesso chiuso

Tipologia: Documento in versione editoriale
Dimensione 2.06 MB
Formato Adobe PDF
2.06 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/1220621
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 1
social impact