Point-of-care brain ultrasound and transcranial doppler or color-coded doppler is being increasingly used as an essential diagnostic and monitoring tool at the bedside of critically ill neonates and children. Brain ultrasound has already established as a cornerstone of daily practice in the management of the critically ill newborn for diagnosis and follow-up of the most common brain diseases, considering the easiness to insonate the brain through transfontanellar window. In critically ill children, doppler based techniques are used to assess cerebral hemodynamics in acute brain injury and recommended for screening patients suffering from sickle cell disease at risk for stroke. However, more evidence is needed regarding the accuracy of doppler based techniques for non-invasive estimation of cerebral perfusion pressure and intracranial pressure, as well as regarding the accuracy of brain ultrasound for diagnosis and monitoring of acute brain parenchyma alterations in children. This review is aimed at providing a comprehensive overview for clinicians of the technical, anatomical, and physiological basics for brain ultrasonography and transcranial doppler or color-coded doppler, and of the current status and future perspectives of their clinical applications in critically ill neonates and children.Conclusion: In critically ill neonates, brain ultrasound for diagnosis and follow-up of the most common cerebral pathologies of the neonatal period may be considered the standard of care. Data are needed about the possible role of doppler techniques for the assessment of cerebral perfusion and vasoreactivity of the critically ill neonate with open fontanelles. In pediatric critical care, doppler based techniques should be routinely adopted to assess and monitor cerebral hemodynamics. New technologies and more evidence are needed to improve the accuracy of brain ultrasound for the assessment of brain parenchyma of critically ill children with fibrous fontanelles.What is Known:center dot In critically ill neonates, brain ultrasound for early diagnosis and follow-up of the most common cerebral and neurovascular pathologies of the neonatal period is a cornerstone of daily practice. In critically ill children, doppler-based techniques are more routinely used to assess cerebral hemodynamics and autoregulation after acute brain injury and to screen patients at risk for vasospasm or stroke (e.g., sickle cell diseases, right-to-left shunts).What is New:center dot In critically ill neonates, research is currently focusing on the use of novel high frequency probes, even higher than 10 MHz, especially for extremely preterm babies. Furthermore, data are needed about the role of doppler based techniques for the assessment of cerebral perfusion and vasoreactivity of the critically ill neonate with open fontanelles, also integrated with a non-invasive assessment of brain oxygenation. In pediatric critical care, new technologies should be developed to improve the accuracy of brain ultrasound for the assessment of brain parenchyma of critically ill children with fibrous fontanelles. Furthermore, large multicenter studies are needed to clarify role and accuracy of doppler-based techniques to assess cerebral perfusion pressure and its changes after treatment interventions.
Point-of-care brain ultrasound and transcranial doppler or color-coded doppler in critically ill neonates and children
Vinci, Francesco;Calandrino, Andrea;Ramenghi, Luca Antonio;
2024-01-01
Abstract
Point-of-care brain ultrasound and transcranial doppler or color-coded doppler is being increasingly used as an essential diagnostic and monitoring tool at the bedside of critically ill neonates and children. Brain ultrasound has already established as a cornerstone of daily practice in the management of the critically ill newborn for diagnosis and follow-up of the most common brain diseases, considering the easiness to insonate the brain through transfontanellar window. In critically ill children, doppler based techniques are used to assess cerebral hemodynamics in acute brain injury and recommended for screening patients suffering from sickle cell disease at risk for stroke. However, more evidence is needed regarding the accuracy of doppler based techniques for non-invasive estimation of cerebral perfusion pressure and intracranial pressure, as well as regarding the accuracy of brain ultrasound for diagnosis and monitoring of acute brain parenchyma alterations in children. This review is aimed at providing a comprehensive overview for clinicians of the technical, anatomical, and physiological basics for brain ultrasonography and transcranial doppler or color-coded doppler, and of the current status and future perspectives of their clinical applications in critically ill neonates and children.Conclusion: In critically ill neonates, brain ultrasound for diagnosis and follow-up of the most common cerebral pathologies of the neonatal period may be considered the standard of care. Data are needed about the possible role of doppler techniques for the assessment of cerebral perfusion and vasoreactivity of the critically ill neonate with open fontanelles. In pediatric critical care, doppler based techniques should be routinely adopted to assess and monitor cerebral hemodynamics. New technologies and more evidence are needed to improve the accuracy of brain ultrasound for the assessment of brain parenchyma of critically ill children with fibrous fontanelles.What is Known:center dot In critically ill neonates, brain ultrasound for early diagnosis and follow-up of the most common cerebral and neurovascular pathologies of the neonatal period is a cornerstone of daily practice. In critically ill children, doppler-based techniques are more routinely used to assess cerebral hemodynamics and autoregulation after acute brain injury and to screen patients at risk for vasospasm or stroke (e.g., sickle cell diseases, right-to-left shunts).What is New:center dot In critically ill neonates, research is currently focusing on the use of novel high frequency probes, even higher than 10 MHz, especially for extremely preterm babies. Furthermore, data are needed about the role of doppler based techniques for the assessment of cerebral perfusion and vasoreactivity of the critically ill neonate with open fontanelles, also integrated with a non-invasive assessment of brain oxygenation. In pediatric critical care, new technologies should be developed to improve the accuracy of brain ultrasound for the assessment of brain parenchyma of critically ill children with fibrous fontanelles. Furthermore, large multicenter studies are needed to clarify role and accuracy of doppler-based techniques to assess cerebral perfusion pressure and its changes after treatment interventions.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.