Nitrite/nitrate poisoning is an emerging problem, with an ongoing escalation of reported self-administration with suicidal intent in several countries. Nitrites toxicity mainly consists of their interaction with hemoglobin (Hb), causing its oxidization to methemoglobin (MetHb). In order to give support to the correct procedures for the analysis of these cases, this study aims to evaluate spontaneous sample degradation and consequent MetHb formation in the typical storage conditions of a forensic toxicology laboratory. Two different types of samples have been used in this study: the first stage of our study consisted of a retrospective analysis of blood samples obtained by judicial autopsies already stored in the toxicology laboratory, collected over four years (2018–2021), while the samples used for the second stage were appositely collected during judicial autopsies. The data obtained by the application of a derivative spectrophotometry method on these samples suggest that there seems not to be a maximum threshold for MetHb formation within which it is possible to state with a sufficient grade of certainty that the concentration of MetHb found is consistent with an ante-mortem formation and is not the result of an artifact due to sample degradation and storage conditions. On the other hand, the results suggest that MetHb formation depends on the time passed between sample collection and analysis, so that a tempestive sample processing, performed as soon as the samples are received in the laboratory, is crucial to obtain the maximum reliability and diagnostic values from the data when MetHb quantitation is necessary.
Evaluation of Spontaneous Overtime Methemoglobin Formation in Post-Mortem Blood Samples from Real Cases in Critical Storage Conditions
Sara Gariglio;
2024-01-01
Abstract
Nitrite/nitrate poisoning is an emerging problem, with an ongoing escalation of reported self-administration with suicidal intent in several countries. Nitrites toxicity mainly consists of their interaction with hemoglobin (Hb), causing its oxidization to methemoglobin (MetHb). In order to give support to the correct procedures for the analysis of these cases, this study aims to evaluate spontaneous sample degradation and consequent MetHb formation in the typical storage conditions of a forensic toxicology laboratory. Two different types of samples have been used in this study: the first stage of our study consisted of a retrospective analysis of blood samples obtained by judicial autopsies already stored in the toxicology laboratory, collected over four years (2018–2021), while the samples used for the second stage were appositely collected during judicial autopsies. The data obtained by the application of a derivative spectrophotometry method on these samples suggest that there seems not to be a maximum threshold for MetHb formation within which it is possible to state with a sufficient grade of certainty that the concentration of MetHb found is consistent with an ante-mortem formation and is not the result of an artifact due to sample degradation and storage conditions. On the other hand, the results suggest that MetHb formation depends on the time passed between sample collection and analysis, so that a tempestive sample processing, performed as soon as the samples are received in the laboratory, is crucial to obtain the maximum reliability and diagnostic values from the data when MetHb quantitation is necessary.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.