Introduction: The optimal bowel preparation strategy to minimise the risk of anastomotic leak is yet to be determined. This study aimed to determine whether oral antibiotics combined with mechanical bowel preparation (MBP+Abx) was associated with a reduced risk of anastomotic leak when compared to mechanical bowel preparation alone (MBP) or no bowel preparation (NBP). Methods: A pre-planned analysis of the European Society of Coloproctology (ESCP) 2017 Left Sided Colorectal Resection audit was performed. Patients undergoing elective left sided colonic or rectal resection with primary anastomosis between 1 January 2017 and 15 March 2017 by any operative approach were included. The primary outcome measure was anastomotic leak. Results: Of 3676 patients across 343 centres in 47 countries, 618 (16.8%) received MBP+ABx, 1945 MBP (52.9%) and 1099 patients NBP (29.9%). Patients undergoing MBP+ABx had the lowest overall rate of anastomotic leak (6.1%, 9.2%, 8.7% respectively) in unadjusted analysis. After case-mix adjustment using a mixed-effects multivariable regression model, MBP+Abx was associated with a lower risk of anastomotic leak (OR 0.52, 0.30–0.92, P = 0.02) but MBP was not (OR 0.92, 0.63–1.36, P = 0.69) compared to NBP. Conclusion: This non-randomised study adds ‘real-world’, contemporaneous, and prospective evidence of the beneficial effects of combined mechanical bowel preparation and oral antibiotics in the prevention of anastomotic leak following left sided colorectal resection across diverse settings. We have also demonstrated limited uptake of this strategy in current international colorectal practice.
Association of mechanical bowel preparation with oral antibiotics and anastomotic leak following left sided colorectal resection: an international, multi-centre, prospective audit
Introduction: The optimal bowel preparation strategy to minimise the risk of anastomotic leak is yet to be determined. This study aimed to determine whether oral antibiotics combined with mechanical bowel preparation (MBP+Abx) was associated with a reduced risk of anastomotic leak when compared to mechanical bowel preparation alone (MBP) or no bowel preparation (NBP). Methods: A pre-planned analysis of the European Society of Coloproctology (ESCP) 2017 Left Sided Colorectal Resection audit was performed. Patients undergoing elective left sided colonic or rectal resection with primary anastomosis between 1 January 2017 and 15 March 2017 by any operative approach were included. The primary outcome measure was anastomotic leak. Results: Of 3676 patients across 343 centres in 47 countries, 618 (16.8%) received MBP+ABx, 1945 MBP (52.9%) and 1099 patients NBP (29.9%). Patients undergoing MBP+ABx had the lowest overall rate of anastomotic leak (6.1%, 9.2%, 8.7% respectively) in unadjusted analysis. After case-mix adjustment using a mixed-effects multivariable regression model, MBP+Abx was associated with a lower risk of anastomotic leak (OR 0.52, 0.30–0.92, P = 0.02) but MBP was not (OR 0.92, 0.63–1.36, P = 0.69) compared to NBP. Conclusion: This non-randomised study adds ‘real-world’, contemporaneous, and prospective evidence of the beneficial effects of combined mechanical bowel preparation and oral antibiotics in the prevention of anastomotic leak following left sided colorectal resection across diverse settings. We have also demonstrated limited uptake of this strategy in current international colorectal practice.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/1202119
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo
Citazioni
ND
55
47
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.