In ultrasound imaging, state-of-the-art methods for transmit beam pattern (TBP) optimization have well-known drawbacks like non-uniform beam width over depth, significant side lobes, and quick energy drop-out beyond the focal region. To overcome these limitations, we develop a TBP optimization approach by focusing on its narrowband approximation and considering transmit delays as free variables instead of linked to specific focal depths. We formulate a non-linear Least Squares problem to minimize the difference between the TBP corresponding to a set of delays and the desired one, modeled as a 2D rectangle elongated along the beam axis. Three metrics are defined to quantitatively evaluate the results. Results obtained by synthetic simulations show that the main lobe width is considerably more intense ( on average) and uniform ( on average) over the whole depth range compared to classical focalized Beam Patterns. The application of the method to elastography shows improvements in the ultrasound energy concentration along a desired axis.

A stochastic approach to delays optimization for narrowband transmit beam pattern in medical ultrasound

Chiara Razzetta;Valentina Candiani;Federico Benvenuto
2024-01-01

Abstract

In ultrasound imaging, state-of-the-art methods for transmit beam pattern (TBP) optimization have well-known drawbacks like non-uniform beam width over depth, significant side lobes, and quick energy drop-out beyond the focal region. To overcome these limitations, we develop a TBP optimization approach by focusing on its narrowband approximation and considering transmit delays as free variables instead of linked to specific focal depths. We formulate a non-linear Least Squares problem to minimize the difference between the TBP corresponding to a set of delays and the desired one, modeled as a 2D rectangle elongated along the beam axis. Three metrics are defined to quantitatively evaluate the results. Results obtained by synthetic simulations show that the main lobe width is considerably more intense ( on average) and uniform ( on average) over the whole depth range compared to classical focalized Beam Patterns. The application of the method to elastography shows improvements in the ultrasound energy concentration along a desired axis.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/1192815
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact