OBJECTIVES: Patients with pectus excavatum (PE) after prior sternotomy for cardiac surgery present unique challenges for repair of PE. Open repairs have been recommended because of concerns about sternal adhesions and cardiac injury. We report a multi-institutional experience with repair utilizing substernal Nuss bars in this patient population. METHODS: Surgeons from the Chest Wall International Group were queried for experience and retrospective data on PE repair using substernal Nuss bars in patients with a history of median sternotomy for cardiac surgery (November 2000 to August 2015). A descriptive analysis was performed. RESULTS: Data for 75 patients were available from 14 centres. The median age at PE repair was 9.5 years (interquartile range 10.9), and the median Haller index was 3.9 (interquartile range 1.43); 56% of the patients were men. The median time to PE repair was 6.4 years (interquartile range 7.886) after prior cardiac surgery. Twelve patients (16%) required resternotomy before support bar placement: 7 preemptively and 5 emergently. Sternal elevation before bar placement was used in 34 patients (45%) and thoracoscopy in 67 patients (89%). Standby with cardiopulmonary bypass was available at 9 centres (64%). Inadvertent cardiac injury occurred in 5 cases (7%) without mortality. CONCLUSIONS: Over a broad range of institutions, substernal Nuss bars were used in PE repair for patients with a history of sternotomy for cardiac surgery. Several technique modifications were reported and may have facilitated repair. Cardiac injury occurred in 7% of cases, and appropriate resources should be available in the event of complications. Prophylactic resternotomy was reported at a minority of centres.

Pectus excavatum repair after sternotomy: The Chest Wall International Group experience with substernal Nuss bars

Yang L.;Torre M.;
2017-01-01

Abstract

OBJECTIVES: Patients with pectus excavatum (PE) after prior sternotomy for cardiac surgery present unique challenges for repair of PE. Open repairs have been recommended because of concerns about sternal adhesions and cardiac injury. We report a multi-institutional experience with repair utilizing substernal Nuss bars in this patient population. METHODS: Surgeons from the Chest Wall International Group were queried for experience and retrospective data on PE repair using substernal Nuss bars in patients with a history of median sternotomy for cardiac surgery (November 2000 to August 2015). A descriptive analysis was performed. RESULTS: Data for 75 patients were available from 14 centres. The median age at PE repair was 9.5 years (interquartile range 10.9), and the median Haller index was 3.9 (interquartile range 1.43); 56% of the patients were men. The median time to PE repair was 6.4 years (interquartile range 7.886) after prior cardiac surgery. Twelve patients (16%) required resternotomy before support bar placement: 7 preemptively and 5 emergently. Sternal elevation before bar placement was used in 34 patients (45%) and thoracoscopy in 67 patients (89%). Standby with cardiopulmonary bypass was available at 9 centres (64%). Inadvertent cardiac injury occurred in 5 cases (7%) without mortality. CONCLUSIONS: Over a broad range of institutions, substernal Nuss bars were used in PE repair for patients with a history of sternotomy for cardiac surgery. Several technique modifications were reported and may have facilitated repair. Cardiac injury occurred in 7% of cases, and appropriate resources should be available in the event of complications. Prophylactic resternotomy was reported at a minority of centres.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/1162438
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 20
social impact