Partial Body Cryostimulation (PBC) involves a very cold air flow directed to the body of subjects with minimal clothing. PBC is performed in a rapid timeframe, inside an on-purposed designed cryo-cabin. Recently, cryo-cabins have been built with different energy systems, however a validation study on relative thermal responses is missing. This study was aimed at comparing thermal responses following a PBC in an electrically powered cryo-cabin based on forced convection or into a standard nitrogen-fueled cryo-cabin. In a randomized crossover fashion, thirty-six subjects (F=20; M=16) underwent both cryo-exposures lasting 150 s each. Thermal responses were assessed before and immediately after completing each PBC session. Mixed model analysis of variance revealed a significantly colder temperature after electric PBC in all the body regions (except for the thighs) with respect to a standard nitrogen based PBC (F: 16.4 ± 1.4 vs 18 ± 5.8 °C; M: 16.4 ± 1.7 vs 20.9 ± 4 °C). Moreover, a significant lower thermal discomfort was perceived at the end of electric PBC as compared to that one felt following standard PBC. For the first time, the safety and thermo-effectiveness of an electric cryo-cabin based on forced convection was ensured. This methodology can be viable for practitioners of PBC and clinicians.

Thermal responses induced by nitrogen and forced convection based partial-body cryostimulation

Bisio, Ambra;Faelli, Emanuela;Ruggeri, Piero;
2023-01-01

Abstract

Partial Body Cryostimulation (PBC) involves a very cold air flow directed to the body of subjects with minimal clothing. PBC is performed in a rapid timeframe, inside an on-purposed designed cryo-cabin. Recently, cryo-cabins have been built with different energy systems, however a validation study on relative thermal responses is missing. This study was aimed at comparing thermal responses following a PBC in an electrically powered cryo-cabin based on forced convection or into a standard nitrogen-fueled cryo-cabin. In a randomized crossover fashion, thirty-six subjects (F=20; M=16) underwent both cryo-exposures lasting 150 s each. Thermal responses were assessed before and immediately after completing each PBC session. Mixed model analysis of variance revealed a significantly colder temperature after electric PBC in all the body regions (except for the thighs) with respect to a standard nitrogen based PBC (F: 16.4 ± 1.4 vs 18 ± 5.8 °C; M: 16.4 ± 1.7 vs 20.9 ± 4 °C). Moreover, a significant lower thermal discomfort was perceived at the end of electric PBC as compared to that one felt following standard PBC. For the first time, the safety and thermo-effectiveness of an electric cryo-cabin based on forced convection was ensured. This methodology can be viable for practitioners of PBC and clinicians.
File in questo prodotto:
File Dimensione Formato  
Thermal responses induced by nitrogen.pdf

accesso chiuso

Tipologia: Documento in versione editoriale
Dimensione 2.01 MB
Formato Adobe PDF
2.01 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/1138338
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact