Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
IRIS
The KM3NeT collaboration is constructing two large neutrino detectors in the Mediterranean Sea: KM3NeT/ARCA, located near Sicily and aiming at neutrino astronomy, and KM3NeT/ORCA, located near Toulon and designed for neutrino oscillation studies. The two detectors, together, will have hundreds of Detection Units (DUs) with 18 Digital Optical Modules (DOMs) maintained vertical by buoyancy, forming a large 3D optical array for detecting the Cherenkov light produced by particle produced in neutrino interactions. To properly reconstruct the direction of the incoming neutrino, the position of the DOMs must be known precisely with an accuracy of less than 10 cm, and since the DUs are affected by sea current the position will be measured every 10 minutes. For this purpose, there are acoustic and orientation sensors inside the DOMs. An Attitude Heading Reference System (AHRS) chip provides the components values of the Acceleration and Magnetic field in the DOM, from which it is possible to calculate Yaw, Pitch, and Roll for each floor of the line. A piezo sensor detects the signals from fixed acoustic emitters on the sea floor, so to position it by trilateration. Data from these sensors are used as an input to reconstruct the shape of the entire line based on a DU Line Fit mechanical model. This proceeding presents an overview of the KM3NeT monitoring system, as well as the line fit model and its results.
KM3NeT Detection Unit Line Fit reconstruction using positioning sensors data
The KM3NeT collaboration is constructing two large neutrino detectors in the Mediterranean Sea: KM3NeT/ARCA, located near Sicily and aiming at neutrino astronomy, and KM3NeT/ORCA, located near Toulon and designed for neutrino oscillation studies. The two detectors, together, will have hundreds of Detection Units (DUs) with 18 Digital Optical Modules (DOMs) maintained vertical by buoyancy, forming a large 3D optical array for detecting the Cherenkov light produced by particle produced in neutrino interactions. To properly reconstruct the direction of the incoming neutrino, the position of the DOMs must be known precisely with an accuracy of less than 10 cm, and since the DUs are affected by sea current the position will be measured every 10 minutes. For this purpose, there are acoustic and orientation sensors inside the DOMs. An Attitude Heading Reference System (AHRS) chip provides the components values of the Acceleration and Magnetic field in the DOM, from which it is possible to calculate Yaw, Pitch, and Roll for each floor of the line. A piezo sensor detects the signals from fixed acoustic emitters on the sea floor, so to position it by trilateration. Data from these sensors are used as an input to reconstruct the shape of the entire line based on a DU Line Fit mechanical model. This proceeding presents an overview of the KM3NeT monitoring system, as well as the line fit model and its results.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/1107755
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo
Citazioni
ND
0
0
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.