Accurate and rapid molecular diagnosis of COVID-19 is a crucial step to tackle the ongoing pandemic. The primary objective of this study was to estimate the real-world performance of the novel RT-PCR STANDARD M10 SARS-CoV-2 assay in a large number of nasopharyngeal (NP) specimens eluted in universal transport medium. The secondary objective was to evaluate the compatibility of this kit in testing NP samples eluted in an inactivated transport medium (essential for point-of-care testing) and lower respiratory tract (LRT) specimens, which are commonly collected in critical care. A total of 591 samples were analyzed. Compared with the standard extraction-based RT-PCR Allplex 2019-nCoV (time-to-result of 270 min), the sensitivities of the STANDARD M10 were 100% (95% CI: 98.1-100%), 95.5% (95% CI: 91.7-97.6%), and 99.5% (95% CI: 97.2-99.9%) for >= 1 gene, the ORF1ab gene, and the E gene, respectively, while the specificity was 100% (95% CI: 98.7-100%). The diagnostic accuracy was 100% in testing both NP samples eluted in an inactivated transport medium and LRT specimens. STANDARD M10 reliably detects SARS-CoV-2 in 60 min, may be used as a POC tool, and is suitable for testing LRT specimens in the critical care setting.
Comparative Diagnostic Accuracy of the {STANDARD} M10 Assay for the Molecular Diagnosis of {SARS}-{CoV}-2 in the Point-of-Care and Critical Care Settings
Alexander Domnich;Andrea Orsi;Carlo-Simone Trombetta;Elisabetta Costa;Giulia Guarona;Bianca Bruzzone;Giancarlo Icardi
2022-01-01
Abstract
Accurate and rapid molecular diagnosis of COVID-19 is a crucial step to tackle the ongoing pandemic. The primary objective of this study was to estimate the real-world performance of the novel RT-PCR STANDARD M10 SARS-CoV-2 assay in a large number of nasopharyngeal (NP) specimens eluted in universal transport medium. The secondary objective was to evaluate the compatibility of this kit in testing NP samples eluted in an inactivated transport medium (essential for point-of-care testing) and lower respiratory tract (LRT) specimens, which are commonly collected in critical care. A total of 591 samples were analyzed. Compared with the standard extraction-based RT-PCR Allplex 2019-nCoV (time-to-result of 270 min), the sensitivities of the STANDARD M10 were 100% (95% CI: 98.1-100%), 95.5% (95% CI: 91.7-97.6%), and 99.5% (95% CI: 97.2-99.9%) for >= 1 gene, the ORF1ab gene, and the E gene, respectively, while the specificity was 100% (95% CI: 98.7-100%). The diagnostic accuracy was 100% in testing both NP samples eluted in an inactivated transport medium and LRT specimens. STANDARD M10 reliably detects SARS-CoV-2 in 60 min, may be used as a POC tool, and is suitable for testing LRT specimens in the critical care setting.File | Dimensione | Formato | |
---|---|---|---|
jcm-11-02465-2.pdf
accesso aperto
Tipologia:
Documento in versione editoriale
Dimensione
528.8 kB
Formato
Adobe PDF
|
528.8 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.