The design for an inductive superconducting quantum interference proximity transistor with enhanced performance, the L-SQUIPT, is presented and analyzed. The interferometer is based on a double-loop structure, where each ring comprises a superconductor-normal-metal-superconductor mesoscopic Joseph-son weak link and the readout electrode is implemented in the form of a superconducting tunnel probe. Our design allows us to both improve the coupling of the transistor to the external magnetic field and increase the characteristic magnetic flux transfer functions, thereby leading to an improved ultrasensitive quantum limited magnetometer. The L-SQUIPT behavior is analyzed in both the dissipative and the dissipationless Josephson-like operation modes, in the latter case by exploiting both an inductive and a dispersive read-out scheme. The improved performance makes the L-SQUIPT promising for magnetic flux detection as well as for specific applications in quantum technology, where a responsive dispersive magnetometry at millikelvin temperatures is required.

Inductive Superconducting Quantum Interference Proximity Transistor: The L-SQUIPT

Paolo Solinas;
2022-01-01

Abstract

The design for an inductive superconducting quantum interference proximity transistor with enhanced performance, the L-SQUIPT, is presented and analyzed. The interferometer is based on a double-loop structure, where each ring comprises a superconductor-normal-metal-superconductor mesoscopic Joseph-son weak link and the readout electrode is implemented in the form of a superconducting tunnel probe. Our design allows us to both improve the coupling of the transistor to the external magnetic field and increase the characteristic magnetic flux transfer functions, thereby leading to an improved ultrasensitive quantum limited magnetometer. The L-SQUIPT behavior is analyzed in both the dissipative and the dissipationless Josephson-like operation modes, in the latter case by exploiting both an inductive and a dispersive read-out scheme. The improved performance makes the L-SQUIPT promising for magnetic flux detection as well as for specific applications in quantum technology, where a responsive dispersive magnetometry at millikelvin temperatures is required.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/1103377
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact