The paper deals with the Ground-Climate-Pipeline system and provides requirements for a continuous automated monitoring system. To prevent accidents on pipelines and mitigate their consequences, it is proposed to monitor the condition of the Ground-Climate-Pipeline system in time. The parameters for which it is necessary to organize continuous complex monitoring are given. The recommendations on placing the complex of technical means of control points are offered.

Requirements for the automated monitoring system to reduce environmental risk during operation of trunk pipelines

Rozhok A.;Revetria R.
2021-01-01

Abstract

The paper deals with the Ground-Climate-Pipeline system and provides requirements for a continuous automated monitoring system. To prevent accidents on pipelines and mitigate their consequences, it is proposed to monitor the condition of the Ground-Climate-Pipeline system in time. The parameters for which it is necessary to organize continuous complex monitoring are given. The recommendations on placing the complex of technical means of control points are offered.
File in questo prodotto:
File Dimensione Formato  
Rozhok_2021_IOP_Conf._Ser.:_Earth_Environ._Sci._864_012049.pdf

accesso aperto

Descrizione: Contributo in atti di convegno
Tipologia: Documento in versione editoriale
Dimensione 705.31 kB
Formato Adobe PDF
705.31 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/1095958
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact