A vaulted free-standing canopy roof to be built in a University Campus is investigated by wind tunnel experiments to address the lack of information for this structural shape. First set of tests investigates the model in isolated configuration; second set reproduces the nearby buildings as well as the topography of the surroundings; third set is carried out sealing the building envelope. Mean and peak pressure coefficients are then estimated over the outer and inner surface, also supplying the net values. At the best knowledge of the authors, there are only two well documented experiments on this topic, without information available about peak values. Comparison of results obtained in the different configurations as well as with other wind tunnel tests on vaulted canopies underlines the importance of reproducing the correct geometry of the structure and its details, such as eaves and skylight, for the reliable definition of wind loads, in addition to nearby buildings and surroundings when the canopy is placed in its real position. Finally, a proposal for wind pressure zoning is provided, which can be useful to define design criteria as well as for regulatory use.

Wind pressure measurements on a vaulted canopy roof

Pagnini L.;Torre S.;Freda A.;Piccardo G.
2022-01-01

Abstract

A vaulted free-standing canopy roof to be built in a University Campus is investigated by wind tunnel experiments to address the lack of information for this structural shape. First set of tests investigates the model in isolated configuration; second set reproduces the nearby buildings as well as the topography of the surroundings; third set is carried out sealing the building envelope. Mean and peak pressure coefficients are then estimated over the outer and inner surface, also supplying the net values. At the best knowledge of the authors, there are only two well documented experiments on this topic, without information available about peak values. Comparison of results obtained in the different configurations as well as with other wind tunnel tests on vaulted canopies underlines the importance of reproducing the correct geometry of the structure and its details, such as eaves and skylight, for the reliable definition of wind loads, in addition to nearby buildings and surroundings when the canopy is placed in its real position. Finally, a proposal for wind pressure zoning is provided, which can be useful to define design criteria as well as for regulatory use.
File in questo prodotto:
File Dimensione Formato  
2022_JWEIA_wind pressure measurements on a vaulted canopy roof_draft.pdf

accesso chiuso

Descrizione: articolo principale
Tipologia: Documento in versione editoriale
Dimensione 2.02 MB
Formato Adobe PDF
2.02 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/1074888
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact