Aims. This study is aimed at providing the first demonstration of STIX Fourier-transform X-ray imaging using semi-calibrated (amplitude-only) visibility data acquired during Solar Orbiter's cruise phase. Methods. We used a parametric imaging approach whereby STIX visibility amplitudes are fitted by means of two non-linear optimization methods: a fast meta-heuristic technique inspired by social behavior and a Bayesian Monte Carlo sampling method that, although slower, provides a better way of quantifying the uncertainties. Results. When applied to a set of solar flare visibility amplitudes recorded by STIX on November 18, 2020, the two parametric methods provide very coherent results. The analysis also demonstrates the ability of STIX to reconstruct data at a high time resolution and, from a spectral viewpoint, it shows the reliability of a double-source scenario that is consistent with a thermal versus nonthermal interpretation. Conclusions. In this preliminary analysis of STIX imaging based only on visibility amplitudes, we formulate the imaging problem as a non-linear parametric issue addressed by means of two high-performance optimization techniques that both show the ability to sample the parametric space in an effective fashion, thus avoiding any local minima.

Imaging from STIX visibility amplitudes

Massa P.;Perracchione E.;Garbarino S.;Benvenuto F.;Piana M.;
2021-01-01

Abstract

Aims. This study is aimed at providing the first demonstration of STIX Fourier-transform X-ray imaging using semi-calibrated (amplitude-only) visibility data acquired during Solar Orbiter's cruise phase. Methods. We used a parametric imaging approach whereby STIX visibility amplitudes are fitted by means of two non-linear optimization methods: a fast meta-heuristic technique inspired by social behavior and a Bayesian Monte Carlo sampling method that, although slower, provides a better way of quantifying the uncertainties. Results. When applied to a set of solar flare visibility amplitudes recorded by STIX on November 18, 2020, the two parametric methods provide very coherent results. The analysis also demonstrates the ability of STIX to reconstruct data at a high time resolution and, from a spectral viewpoint, it shows the reliability of a double-source scenario that is consistent with a thermal versus nonthermal interpretation. Conclusions. In this preliminary analysis of STIX imaging based only on visibility amplitudes, we formulate the imaging problem as a non-linear parametric issue addressed by means of two high-performance optimization techniques that both show the ability to sample the parametric space in an effective fashion, thus avoiding any local minima.
File in questo prodotto:
File Dimensione Formato  
aa40946-21.pdf

accesso chiuso

Tipologia: Documento in versione editoriale
Dimensione 567.43 kB
Formato Adobe PDF
567.43 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/1066508
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact