Objective. The COVID-19 pandemic has caused significant impact on healthcare systems worldwide. The rate of infected healthcare workers is > 10% in Italy. Within this dramatic scenario, the development of new personal protective equipment (PPE) devices is manda-tory. This study focuses on validation of modified full-face snorkel masks (MFFSM) as safe and protective equipment against SARS-CoV-2 infection during diagnostic and therapeutic procedures on the upper aerodigestive tract. Methods. Five different MFFSM were tested during otolaryngological surgery and in anaesthesia procedures. Data were collected through an online survey to assess the feedback of op-erators. pO2 and pCO2 monitoring values during procedures were recorded in selected cases. Results. All five MFFSM tested were easy to use and gave all operators a sound “feeling” of protection. All clinicians involved had common agreement regarding safety and the user-friendly format. Conclusions. In the future, specific development of different type of masks for protection in the operating room, intensive care units and/or office will be possible as a joint venture between clinicians and developers. Goals for clinicians include better definition of needs and priorities, while developers can devote their expertise to produce devices that meet medical requirements.

Overview of different modified full-face snorkelling masks for intraoperative protection

Vicini C.;Fragale M.;Cacco T.;Sampieri C.;Guastini L.;Castello E.;Parrinello G.;Peretti G.
2020-01-01

Abstract

Objective. The COVID-19 pandemic has caused significant impact on healthcare systems worldwide. The rate of infected healthcare workers is > 10% in Italy. Within this dramatic scenario, the development of new personal protective equipment (PPE) devices is manda-tory. This study focuses on validation of modified full-face snorkel masks (MFFSM) as safe and protective equipment against SARS-CoV-2 infection during diagnostic and therapeutic procedures on the upper aerodigestive tract. Methods. Five different MFFSM were tested during otolaryngological surgery and in anaesthesia procedures. Data were collected through an online survey to assess the feedback of op-erators. pO2 and pCO2 monitoring values during procedures were recorded in selected cases. Results. All five MFFSM tested were easy to use and gave all operators a sound “feeling” of protection. All clinicians involved had common agreement regarding safety and the user-friendly format. Conclusions. In the future, specific development of different type of masks for protection in the operating room, intensive care units and/or office will be possible as a joint venture between clinicians and developers. Goals for clinicians include better definition of needs and priorities, while developers can devote their expertise to produce devices that meet medical requirements.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/1066420
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact