This paper presents a Model Predictive Controller (MPC) operating an SOFC Gas Turbine hybrid plant at end-of-life performance condition. Its performance was assessed with experimental tests showing a comparison with a Proportional Integral Derivative (PID) control system. The hybrid system operates in grid-connected mode, i.e. at variable speed condition of the turbine. The control system faces a multivariable constrained problem, as it must operate the plant into safety conditions while pursuing its objectives. The goal is to test whether a linearized controller design for normal operating condition is able to govern a system which is affected by strong performance degradation. The control performance was demonstrated in a cyber-physical emulator test rig designed for experimental analyses on such hybrid systems. This laboratory facility is based on the coupling of a 100 kW recuperated microturbine with a fuel cell emulation system based on vessels for both anodic and cathodic sides. The components not physically present in the rig were studied with a real-time model running in parallel with the plant. Model output values were used as set-point data for obtaining in the rig (in real-time mode) the effect of the fuel cell system. The result comparison of the MPC tool against a PID control system was carried out considering several plant properties and the related constraints. Both systems succeeded in managing the plant, still the MPC performed better in terms of smoothing temperature gradient and peaks.

Advanced Control System for Grid-Connected SOFC Hybrid Plants: Experimental Verification in Cyber-Physical Mode

Ferrari Mario L.;Rossi Iacopo;Sorce Alessandro;Massardo
2019-01-01

Abstract

This paper presents a Model Predictive Controller (MPC) operating an SOFC Gas Turbine hybrid plant at end-of-life performance condition. Its performance was assessed with experimental tests showing a comparison with a Proportional Integral Derivative (PID) control system. The hybrid system operates in grid-connected mode, i.e. at variable speed condition of the turbine. The control system faces a multivariable constrained problem, as it must operate the plant into safety conditions while pursuing its objectives. The goal is to test whether a linearized controller design for normal operating condition is able to govern a system which is affected by strong performance degradation. The control performance was demonstrated in a cyber-physical emulator test rig designed for experimental analyses on such hybrid systems. This laboratory facility is based on the coupling of a 100 kW recuperated microturbine with a fuel cell emulation system based on vessels for both anodic and cathodic sides. The components not physically present in the rig were studied with a real-time model running in parallel with the plant. Model output values were used as set-point data for obtaining in the rig (in real-time mode) the effect of the fuel cell system. The result comparison of the MPC tool against a PID control system was carried out considering several plant properties and the related constraints. Both systems succeeded in managing the plant, still the MPC performed better in terms of smoothing temperature gradient and peaks.
2019
978-0-7918-5860-8
File in questo prodotto:
File Dimensione Formato  
GT2019-90379.pdf

accesso chiuso

Tipologia: Documento in versione editoriale
Dimensione 2.59 MB
Formato Adobe PDF
2.59 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/952470
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact