ABSTRACT The present study examines the performance of a hybrid air-conditioning system in which a vapour compression inverse cycle is integrated with an air dehumidification system working with hygroscopic solution and hydrophobic membrane. This approach may prove to be a valid alternative to the traditional summertime air-conditioning system, which involves cooling the air to below its dew point and subsequently reheating it. The system examined simultaneously cools and dehumidifies the air in an air-LiCl solution membrane vapour exchanger before it enters the conditioned environment. The LiCl solution is cooled by means of a vapour compression inverse cycle that uses the refrigerant KLEA 407C. The heat rejected by the condenser is used to regenerate the solution. A SIMULINK calculation programme was used to simulate the system in steady-state conditions. The performance of the system was analysed on varying significant operating parameters and was compared with that of a traditional direct-expansion air-conditioning plant. The results of the simulations revealed significant power saving which, in certain operating conditions, was as much as 50 %.

Vapour compression and liquid desiccant hybrid system for air conditioning

BERGERO, STEFANO;CHIARI, ANNA;NANNEI, ENRICO
2006-01-01

Abstract

ABSTRACT The present study examines the performance of a hybrid air-conditioning system in which a vapour compression inverse cycle is integrated with an air dehumidification system working with hygroscopic solution and hydrophobic membrane. This approach may prove to be a valid alternative to the traditional summertime air-conditioning system, which involves cooling the air to below its dew point and subsequently reheating it. The system examined simultaneously cools and dehumidifies the air in an air-LiCl solution membrane vapour exchanger before it enters the conditioned environment. The LiCl solution is cooled by means of a vapour compression inverse cycle that uses the refrigerant KLEA 407C. The heat rejected by the condenser is used to regenerate the solution. A SIMULINK calculation programme was used to simulate the system in steady-state conditions. The performance of the system was analysed on varying significant operating parameters and was compared with that of a traditional direct-expansion air-conditioning plant. The results of the simulations revealed significant power saving which, in certain operating conditions, was as much as 50 %.
2006
9780791837795
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/252301
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 0
social impact