In Europe, buildings are responsible for 40% of the energy consumption and 36% of the CO2 emissions. Space heating largely contributes to these energy and climate impacts. Passive solar heating systems, as sunspaces, can contribute to increase solar heat gains, reducing space heating energy demand and the related use of fossil fuels. Careful design and local climatic considerations are essential to optimize the performance of sunspaces. In this study experimental field monitoring, dynamic modelling and steady-state methods are applied to analyse the thermal behaviour of an attached sunspace in an Italian existing building, as well as its potential contribution to the building's energy balance. Design modifications for improved thermal performance of the sunspace are investigated. The results show overall agreement between the dynamic modellings and experimental monitoring of the sunspace and indicate that the sunspace's indoor air temperature and hence solar energy gains are significantly increased with the design modifications, in contrast to the existing configuration. Maximum temperatures between 44 and 48 °C were observed for the existing and a modified alternative of the analysed sunspace. The dynamic simulation model and design modifications presented in this study can serve as basis for assessment and optimal configurations of sunspaces in their design stage.
Design optimization of a building attached sunspace through experimental monitoring and dynamic modelling
Giachetta A.;
2020-01-01
Abstract
In Europe, buildings are responsible for 40% of the energy consumption and 36% of the CO2 emissions. Space heating largely contributes to these energy and climate impacts. Passive solar heating systems, as sunspaces, can contribute to increase solar heat gains, reducing space heating energy demand and the related use of fossil fuels. Careful design and local climatic considerations are essential to optimize the performance of sunspaces. In this study experimental field monitoring, dynamic modelling and steady-state methods are applied to analyse the thermal behaviour of an attached sunspace in an Italian existing building, as well as its potential contribution to the building's energy balance. Design modifications for improved thermal performance of the sunspace are investigated. The results show overall agreement between the dynamic modellings and experimental monitoring of the sunspace and indicate that the sunspace's indoor air temperature and hence solar energy gains are significantly increased with the design modifications, in contrast to the existing configuration. Maximum temperatures between 44 and 48 °C were observed for the existing and a modified alternative of the analysed sunspace. The dynamic simulation model and design modifications presented in this study can serve as basis for assessment and optimal configurations of sunspaces in their design stage.File | Dimensione | Formato | |
---|---|---|---|
e3sconf_nsb2020_03010.pdf
accesso aperto
Tipologia:
Documento in versione editoriale
Dimensione
2.91 MB
Formato
Adobe PDF
|
2.91 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.