Introduction: The surface area of exposed metal in a trabecular-titanium acetabular component is wider compared to traditional-titanium implants. The purpose of this study is to establish if this increase in surface area can lead to a significant increase in systemic metal levels. Methods: 19 patients with conventional acetabular component and 19 with trabecular-titanium cup were compared. Aluminum, Vanadium and Titanium in blood and urine were assessed before surgery and at intervals for 2 years. The samples were analysed using an inductively coupled plasma mass spectrometry. Results: Patients with trabecular-titanium did not have significantly higher metal ion levels compared to patients with conventional cups up to 2 years. A trend over time was statistically significant in both blood and urine for aluminum and titanium concentrations. Conclusions: The three-dimensionality and the wide surface of the trabecular-titanium acetabular component did not affect metal ion release compared to traditional implants after 2 years.
Does metal porosity affect metal ion release in blood and urine following total hip arthroplasty? A short term study
Ferracini R.;
2018-01-01
Abstract
Introduction: The surface area of exposed metal in a trabecular-titanium acetabular component is wider compared to traditional-titanium implants. The purpose of this study is to establish if this increase in surface area can lead to a significant increase in systemic metal levels. Methods: 19 patients with conventional acetabular component and 19 with trabecular-titanium cup were compared. Aluminum, Vanadium and Titanium in blood and urine were assessed before surgery and at intervals for 2 years. The samples were analysed using an inductively coupled plasma mass spectrometry. Results: Patients with trabecular-titanium did not have significantly higher metal ion levels compared to patients with conventional cups up to 2 years. A trend over time was statistically significant in both blood and urine for aluminum and titanium concentrations. Conclusions: The three-dimensionality and the wide surface of the trabecular-titanium acetabular component did not affect metal ion release compared to traditional implants after 2 years.File | Dimensione | Formato | |
---|---|---|---|
Does metal porosity affect metal ion release in blood and urine following total hip arthro.pdf
accesso chiuso
Tipologia:
Documento in versione editoriale
Dimensione
663.32 kB
Formato
Adobe PDF
|
663.32 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.