Background: Calcific coronary lesions can be so resistant to prevent symmetric stent dilatation with high risk of ISR/thrombosis. The aim of the current study is to evaluate the safety and efficacy of super high-pressure dilatation (>30-to-45Atm) using a dedicated NC-balloon (OPN, SIS-Medical-AG, Winterthur-Switzerland). Methods: We retrospectively evaluated 326 consecutive undilatable lesions in which conventional NC-balloons failed to achieve adequate post-dilatation luminal gain. After the failed attempt an OPN-balloon was inflated up to achieve a uniform balloon expansion (maximal dilatation pressure of 45–50 Atm). Lesions were divided into two groups according to the final inflation pressure: Group-I: lesion responsive to 30-40Atm and Group-2:>40 Atm. Angiographic success was defined as residual angiographic stenosis<30% assessed by visual estimation with TIMI3-flow. Procedural success was defined as the achievement of angiographic success without any MACE. Results: Angiographic success was achieved in 97.5%, procedural success in 96.6%; 53% of the lesions were responsive to a slower inflation pressure (Group I) while in the remaining 47%, the optimal expansion required a pressure > 40ATM (Group II). In 3 patients coronary rupture occurred after balloon inflation and was successfully treated with stent implantation with a final TIMI3-flow. The OPN alone was able to achieve adequate expansion in >90%. 0.9% days MACE were reported. Conclusion: The OPN-dedicated high-pressure balloon provides an effective and safe strategy for treatment of severe resistant coronary lesions.

Clinical experience with very high-pressure dilatation for resistant coronary lesions

Porto I.;
2019-01-01

Abstract

Background: Calcific coronary lesions can be so resistant to prevent symmetric stent dilatation with high risk of ISR/thrombosis. The aim of the current study is to evaluate the safety and efficacy of super high-pressure dilatation (>30-to-45Atm) using a dedicated NC-balloon (OPN, SIS-Medical-AG, Winterthur-Switzerland). Methods: We retrospectively evaluated 326 consecutive undilatable lesions in which conventional NC-balloons failed to achieve adequate post-dilatation luminal gain. After the failed attempt an OPN-balloon was inflated up to achieve a uniform balloon expansion (maximal dilatation pressure of 45–50 Atm). Lesions were divided into two groups according to the final inflation pressure: Group-I: lesion responsive to 30-40Atm and Group-2:>40 Atm. Angiographic success was defined as residual angiographic stenosis<30% assessed by visual estimation with TIMI3-flow. Procedural success was defined as the achievement of angiographic success without any MACE. Results: Angiographic success was achieved in 97.5%, procedural success in 96.6%; 53% of the lesions were responsive to a slower inflation pressure (Group I) while in the remaining 47%, the optimal expansion required a pressure > 40ATM (Group II). In 3 patients coronary rupture occurred after balloon inflation and was successfully treated with stent implantation with a final TIMI3-flow. The OPN alone was able to achieve adequate expansion in >90%. 0.9% days MACE were reported. Conclusion: The OPN-dedicated high-pressure balloon provides an effective and safe strategy for treatment of severe resistant coronary lesions.
File in questo prodotto:
File Dimensione Formato  
secco2019.pdf

accesso chiuso

Tipologia: Documento in versione editoriale
Dimensione 1.41 MB
Formato Adobe PDF
1.41 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/962344
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 49
  • ???jsp.display-item.citation.isi??? 40
social impact