Background: Calcific coronary lesions can be so resistant to prevent symmetric stent dilatation with high risk of ISR/thrombosis. The aim of the current study is to evaluate the safety and efficacy of super high-pressure dilatation (>30-to-45Atm) using a dedicated NC-balloon (OPN, SIS-Medical-AG, Winterthur-Switzerland). Methods: We retrospectively evaluated 326 consecutive undilatable lesions in which conventional NC-balloons failed to achieve adequate post-dilatation luminal gain. After the failed attempt an OPN-balloon was inflated up to achieve a uniform balloon expansion (maximal dilatation pressure of 45–50 Atm). Lesions were divided into two groups according to the final inflation pressure: Group-I: lesion responsive to 30-40Atm and Group-2:>40 Atm. Angiographic success was defined as residual angiographic stenosis<30% assessed by visual estimation with TIMI3-flow. Procedural success was defined as the achievement of angiographic success without any MACE. Results: Angiographic success was achieved in 97.5%, procedural success in 96.6%; 53% of the lesions were responsive to a slower inflation pressure (Group I) while in the remaining 47%, the optimal expansion required a pressure > 40ATM (Group II). In 3 patients coronary rupture occurred after balloon inflation and was successfully treated with stent implantation with a final TIMI3-flow. The OPN alone was able to achieve adequate expansion in >90%. 0.9% days MACE were reported. Conclusion: The OPN-dedicated high-pressure balloon provides an effective and safe strategy for treatment of severe resistant coronary lesions.
Clinical experience with very high-pressure dilatation for resistant coronary lesions
Porto I.;
2019-01-01
Abstract
Background: Calcific coronary lesions can be so resistant to prevent symmetric stent dilatation with high risk of ISR/thrombosis. The aim of the current study is to evaluate the safety and efficacy of super high-pressure dilatation (>30-to-45Atm) using a dedicated NC-balloon (OPN, SIS-Medical-AG, Winterthur-Switzerland). Methods: We retrospectively evaluated 326 consecutive undilatable lesions in which conventional NC-balloons failed to achieve adequate post-dilatation luminal gain. After the failed attempt an OPN-balloon was inflated up to achieve a uniform balloon expansion (maximal dilatation pressure of 45–50 Atm). Lesions were divided into two groups according to the final inflation pressure: Group-I: lesion responsive to 30-40Atm and Group-2:>40 Atm. Angiographic success was defined as residual angiographic stenosis<30% assessed by visual estimation with TIMI3-flow. Procedural success was defined as the achievement of angiographic success without any MACE. Results: Angiographic success was achieved in 97.5%, procedural success in 96.6%; 53% of the lesions were responsive to a slower inflation pressure (Group I) while in the remaining 47%, the optimal expansion required a pressure > 40ATM (Group II). In 3 patients coronary rupture occurred after balloon inflation and was successfully treated with stent implantation with a final TIMI3-flow. The OPN alone was able to achieve adequate expansion in >90%. 0.9% days MACE were reported. Conclusion: The OPN-dedicated high-pressure balloon provides an effective and safe strategy for treatment of severe resistant coronary lesions.File | Dimensione | Formato | |
---|---|---|---|
secco2019.pdf
accesso chiuso
Tipologia:
Documento in versione editoriale
Dimensione
1.41 MB
Formato
Adobe PDF
|
1.41 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.