Background: Visual Analogue Scale (VAS) is a validated tool to assess control in allergic rhinitis patients. Objective: The aim of this study was to validate the use of VAS in the MASK-rhinitis (MACVIA-ARIA Sentinel NetworK for allergic rhinitis) app (Allergy Diary) on smartphones screens to evaluate allergic rhinitis symptoms and disease control. Methods: Each user filled 4 different VAS measuring overall, nasal, ocular, and asthma symptoms at least once. Following COSMIN guidelines, we evaluated internal consistency, (Cronbach's alpha coefficient and test-retest), reliability (intraclass correlation coefficients), sensitivity, and acceptability of the MASK-Rhinitis VAS. Results: Between 1 August 2015 and 31 July 2016, the app was used 14 612 times in 15 countries. A total of 1225 users used it more than once, during the evaluated period. The tool resulted to be statistically satisfactory, showing excellent internal consistency (Cronbach's test > 0.84, test-retest > 0.7), reliability (>0.9), and acceptability. In addition, the tool had a good sensitivity when users (n = 521) answered the VAS twice in less than 3 hours. Conclusions and Clinical Relevance: The MASK-rhinitis VAS is a reliable and valid tool to assess allergic control on smartphone screens, at the population level.

Validation of the MASK-rhinitis visual analogue scale on smartphone screens to assess allergic rhinitis control

Passalacqua, G.;
2017-01-01

Abstract

Background: Visual Analogue Scale (VAS) is a validated tool to assess control in allergic rhinitis patients. Objective: The aim of this study was to validate the use of VAS in the MASK-rhinitis (MACVIA-ARIA Sentinel NetworK for allergic rhinitis) app (Allergy Diary) on smartphones screens to evaluate allergic rhinitis symptoms and disease control. Methods: Each user filled 4 different VAS measuring overall, nasal, ocular, and asthma symptoms at least once. Following COSMIN guidelines, we evaluated internal consistency, (Cronbach's alpha coefficient and test-retest), reliability (intraclass correlation coefficients), sensitivity, and acceptability of the MASK-Rhinitis VAS. Results: Between 1 August 2015 and 31 July 2016, the app was used 14 612 times in 15 countries. A total of 1225 users used it more than once, during the evaluated period. The tool resulted to be statistically satisfactory, showing excellent internal consistency (Cronbach's test > 0.84, test-retest > 0.7), reliability (>0.9), and acceptability. In addition, the tool had a good sensitivity when users (n = 521) answered the VAS twice in less than 3 hours. Conclusions and Clinical Relevance: The MASK-rhinitis VAS is a reliable and valid tool to assess allergic control on smartphone screens, at the population level.
File in questo prodotto:
File Dimensione Formato  
Caimmi_et_al-2017-Clinical_&_Experimental_Allergy.pdf

accesso aperto

Tipologia: Documento in versione editoriale
Dimensione 540.96 kB
Formato Adobe PDF
540.96 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/933881
Citazioni
  • ???jsp.display-item.citation.pmc??? 30
  • Scopus 74
  • ???jsp.display-item.citation.isi??? 68
social impact