This paper proposes a complete experimental / numerical comparison, carried out at the Marine Structures Testing Lab of the University of Genoa, Italy, on the evaluation of the inter-laminar shear strength in composite laminates typically used in the marine industry and offshore wind energy, manufactured including a non-negligible percentage of voids, in order to assess its effects on the inter-laminar shear strength. The specimens originally obtained from larger panels made by preimpregnated fabrics, were manufactured according to the ASTM standard D3846-79, which is the test required by most Classification Societies for the evaluation of the inter-laminar shear strength of composites.

Influence of air inclusions on the marine composites inter-laminar shear strength

GAIOTTI, MARCO;RIZZO, CESARE MARIO
2015-01-01

Abstract

This paper proposes a complete experimental / numerical comparison, carried out at the Marine Structures Testing Lab of the University of Genoa, Italy, on the evaluation of the inter-laminar shear strength in composite laminates typically used in the marine industry and offshore wind energy, manufactured including a non-negligible percentage of voids, in order to assess its effects on the inter-laminar shear strength. The specimens originally obtained from larger panels made by preimpregnated fabrics, were manufactured according to the ASTM standard D3846-79, which is the test required by most Classification Societies for the evaluation of the inter-laminar shear strength of composites.
2015
978-1-880653-89-0
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/809950
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? ND
social impact