The aim of the present article was to present an alternative endovascular treatment for type II thoracoabdominal aortic aneurysm that would have the advantage of limiting the duration of the procedure and the use of contrast. A high-risk patient was admitted to our Vascular Unit for type II thoracoabdominal aneurysm according to Crawford's classification. Two thoracic stent-grafts (Valiant Captivia, Medtronic, Pewaukee, WI, USA), a bifurcated stent-graft (Endurant Medtronic) and two multilayer stents (Cardiatis SA, Isnes, Belgium) were deployed. No postoperative major complications were observed. Operative time and use of contrast material were 45 min and 80 mL, respectively. Computed angiography tomography at 1 and 6 months showed patency of visceral and renal arteries and progressive thrombosis of the aneurysmal sac. This stent-graft treatment in combination with multilayer stent could be an alternative treatment for thoracoabdominal aneurysm in high-risk patients. PMID: 24013540

Stent-graft and multilayer stent for treatment of type II thoracoabdominal aortic aneurysm in a high-risk patient.

PANE, BIANCA;SPINELLA, GIOVANNI SALVATORE GIUSEPPE;PALOMBO, DOMENICO
2013-01-01

Abstract

The aim of the present article was to present an alternative endovascular treatment for type II thoracoabdominal aortic aneurysm that would have the advantage of limiting the duration of the procedure and the use of contrast. A high-risk patient was admitted to our Vascular Unit for type II thoracoabdominal aneurysm according to Crawford's classification. Two thoracic stent-grafts (Valiant Captivia, Medtronic, Pewaukee, WI, USA), a bifurcated stent-graft (Endurant Medtronic) and two multilayer stents (Cardiatis SA, Isnes, Belgium) were deployed. No postoperative major complications were observed. Operative time and use of contrast material were 45 min and 80 mL, respectively. Computed angiography tomography at 1 and 6 months showed patency of visceral and renal arteries and progressive thrombosis of the aneurysmal sac. This stent-graft treatment in combination with multilayer stent could be an alternative treatment for thoracoabdominal aneurysm in high-risk patients. PMID: 24013540
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/746193
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 5
social impact