A method based on capillary electrophoresis has been developed for the analysis of the novel antidepressant drug duloxetine in human plasma. The method makes use of laser-induced fluorescence detection after derivatisation of the analyte with 5-(4,6-dichlorotriazinyl)aminofluorescein at pH 11. A single step liquid/liquid extraction procedure with a mixture of hexane/2-propanol allows the sample clean-up with extraction yields always >or=84% and interference removal. The electrophoretic separation is achieved using uncoated fused silica capillaries (60.0 cm effective length, 75.0 cm total length, 50 microm internal diameter) and a background electrolyte composed of borate buffer (40 mM, pH 10.3), tetrabutylammonium bromide (10 mM), and acetone (10%, v/v). The applied voltage is 20 kV; the samples are injected by pressure (50 mbar x 8 s). The method has been fully validated in terms of linearity range (2.5-150 ng mL(-1)), LOD and LOQ (1.0 and 2.5 ng mL(-1), respectively), precision (R.S.D.<6.7%) and accuracy (recovery >78%). Application to samples obtained from patients under treatment with duloxetine gave good results. The method represents the first application of capillary electrophoresis to the analysis of duloxetine in human plasma

Determination of duloxetine in human plasma by capillary electrophoresis with laser-induced fluorescence detection

AMORE, MARIO;
2009-01-01

Abstract

A method based on capillary electrophoresis has been developed for the analysis of the novel antidepressant drug duloxetine in human plasma. The method makes use of laser-induced fluorescence detection after derivatisation of the analyte with 5-(4,6-dichlorotriazinyl)aminofluorescein at pH 11. A single step liquid/liquid extraction procedure with a mixture of hexane/2-propanol allows the sample clean-up with extraction yields always >or=84% and interference removal. The electrophoretic separation is achieved using uncoated fused silica capillaries (60.0 cm effective length, 75.0 cm total length, 50 microm internal diameter) and a background electrolyte composed of borate buffer (40 mM, pH 10.3), tetrabutylammonium bromide (10 mM), and acetone (10%, v/v). The applied voltage is 20 kV; the samples are injected by pressure (50 mbar x 8 s). The method has been fully validated in terms of linearity range (2.5-150 ng mL(-1)), LOD and LOQ (1.0 and 2.5 ng mL(-1), respectively), precision (R.S.D.<6.7%) and accuracy (recovery >78%). Application to samples obtained from patients under treatment with duloxetine gave good results. The method represents the first application of capillary electrophoresis to the analysis of duloxetine in human plasma
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/503695
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 35
  • ???jsp.display-item.citation.isi??? 29
social impact