An original high-performance liquid chromatographic method with fluorescence detection is presented for the simultaneous determination of the three antiepileptic drugs gabapentin, vigabatrin and topiramate in human plasma. After pre-column derivatisation with dansyl chloride, the analytes were separated on a Hydro-RP column with a mobile phase composed of phosphate buffer (55%) and acetonitrile (45%) and detected at lambda(em)=500 nm, exciting at 300 nm. An original pre-treatment procedure on biological samples, based on solid-phase extraction with MCX cartridges for gabapentin and vigabatrin, and with Plexa cartridges for topiramate, gave high extraction yields (>91%), satisfactory precision (RSD<6.4%) and good selectivity. Linearity was found in the 0.2-50.0 microg mL(-1) range for gabapentin, in the 1.0-100.0 microg mL(-1) range for vigabatrin and in the 1.0-50.0 microg mL(-1) range for topiramate, with limits of detection (LODs) between 0.1 and 0.3 microg mL(-1). After validation, the method was successfully applied to some plasma samples from patients undergoing therapy with one or more of these drugs. Accuracy results were satisfactory (recovery >91%). Therefore, the method seems to be suitable for the therapeutic drug monitoring (TDM) of patients treated with gabapentin, vigabatrin and topiramate

Simultaneous HPLC-F analysis of three recent antiepileptic drugs in human plasma

AMORE, MARIO;
2010-01-01

Abstract

An original high-performance liquid chromatographic method with fluorescence detection is presented for the simultaneous determination of the three antiepileptic drugs gabapentin, vigabatrin and topiramate in human plasma. After pre-column derivatisation with dansyl chloride, the analytes were separated on a Hydro-RP column with a mobile phase composed of phosphate buffer (55%) and acetonitrile (45%) and detected at lambda(em)=500 nm, exciting at 300 nm. An original pre-treatment procedure on biological samples, based on solid-phase extraction with MCX cartridges for gabapentin and vigabatrin, and with Plexa cartridges for topiramate, gave high extraction yields (>91%), satisfactory precision (RSD<6.4%) and good selectivity. Linearity was found in the 0.2-50.0 microg mL(-1) range for gabapentin, in the 1.0-100.0 microg mL(-1) range for vigabatrin and in the 1.0-50.0 microg mL(-1) range for topiramate, with limits of detection (LODs) between 0.1 and 0.3 microg mL(-1). After validation, the method was successfully applied to some plasma samples from patients undergoing therapy with one or more of these drugs. Accuracy results were satisfactory (recovery >91%). Therefore, the method seems to be suitable for the therapeutic drug monitoring (TDM) of patients treated with gabapentin, vigabatrin and topiramate
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/503583
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 37
  • ???jsp.display-item.citation.isi??? 33
social impact