Abstract Introduction: In peripheral nerve ultrasound, the healthy contralateral side may be used as internal control. Therefore, inherent side-to-side differences must be minimal. The goal of this study was to assess intrastudy, intraobserver and interobserver reproducibility of ultrasound in comparative side-to-side evaluation of lower limb nerves Materials and Methods: Lower limb nerves of 60 normal subjects were evaluated by three radiologists. Bilateral sciatic, tibial, common fibular, sural, lateral femoral cutaneous, femoral, obturator and saphenous nerves were evaluated. Results: Overall, side-to-side differences were not statistically significant at any level. In the lower limb nerves, in between-limb comparison, the minimum detectable difference of cross-sectional area ranged from 16.4 mm2 (sciatic nerve at the level of piriformis muscle) to 0.4 mm2 (saphenous nerve). Conclusion: In general, the healthy contralateral side can be used as an internal control.

The reliability of side-to-side ultrasound (US) cross-sectional area measurements of lower extremity nerves in healthy subjects

TAGLIAFICO, ALBERTO;CADONI, ANGELA;MARTINOLI, CARLO
2012-01-01

Abstract

Abstract Introduction: In peripheral nerve ultrasound, the healthy contralateral side may be used as internal control. Therefore, inherent side-to-side differences must be minimal. The goal of this study was to assess intrastudy, intraobserver and interobserver reproducibility of ultrasound in comparative side-to-side evaluation of lower limb nerves Materials and Methods: Lower limb nerves of 60 normal subjects were evaluated by three radiologists. Bilateral sciatic, tibial, common fibular, sural, lateral femoral cutaneous, femoral, obturator and saphenous nerves were evaluated. Results: Overall, side-to-side differences were not statistically significant at any level. In the lower limb nerves, in between-limb comparison, the minimum detectable difference of cross-sectional area ranged from 16.4 mm2 (sciatic nerve at the level of piriformis muscle) to 0.4 mm2 (saphenous nerve). Conclusion: In general, the healthy contralateral side can be used as an internal control.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/382366
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 69
  • ???jsp.display-item.citation.isi??? 63
social impact