Background: To evaluate the diagnostic characteristics of commercially available IgG anti-tTG assays in selective IgA deficiency (SIgAD), we tested different IgG anti-tTG methods and compared the results with those obtained from two other tests: one for IgG anti-gliadin (AGA) and one for IgG to deaminated gliadin peptides (DGP). Methods: 20 CD patients with SIgAD and 113 controls (9 patients with SIgAD without CD; 54 patients with chronic liver disease; 50 healthy subjects) were tested with 9 IgG anti-tTG assays (2 of which are enriched with gliadin peptides), one IgG AGA assay and one IgG anti-DGP assay. Results: Using optimal cutoffs as determined by ROC curves, the sensitivity of IgG anti-tTG methods ranged from 75% (1 kit) to 95% (7 kits) and the specificity from 94% (1 kit) to 100% (5 kits). Sensitivity and specificity were 40% and 87% for IgG AGA, and 80% and 98% for IgG anti-DGP, respectively. Conclusions: All IgG anti-tTG methods evaluated are reliable serologic assays for the diagnosis of CD inpatients with SIgAD and perform better than the gliadin-based assays used in this study. The tests containing both tTG and gliadinic peptides are burdened by a lower specificity than the anti-tTG assays. (c) 2007 Elsevier B.V. All rights reserved.

Testing for IgG class antibodies in celiac disease patients with selective IgA deficiency. A comparison of the diagnostic accuracy of 9 IgG anti-tissue transglutaminase, 1 IgG anti-gliadin and 1 IgG anti-deaminated gliadin peptide antibody assays.

BAGNASCO, MARCELLO;PESCE, GIAMPAOLA;
2007-01-01

Abstract

Background: To evaluate the diagnostic characteristics of commercially available IgG anti-tTG assays in selective IgA deficiency (SIgAD), we tested different IgG anti-tTG methods and compared the results with those obtained from two other tests: one for IgG anti-gliadin (AGA) and one for IgG to deaminated gliadin peptides (DGP). Methods: 20 CD patients with SIgAD and 113 controls (9 patients with SIgAD without CD; 54 patients with chronic liver disease; 50 healthy subjects) were tested with 9 IgG anti-tTG assays (2 of which are enriched with gliadin peptides), one IgG AGA assay and one IgG anti-DGP assay. Results: Using optimal cutoffs as determined by ROC curves, the sensitivity of IgG anti-tTG methods ranged from 75% (1 kit) to 95% (7 kits) and the specificity from 94% (1 kit) to 100% (5 kits). Sensitivity and specificity were 40% and 87% for IgG AGA, and 80% and 98% for IgG anti-DGP, respectively. Conclusions: All IgG anti-tTG methods evaluated are reliable serologic assays for the diagnosis of CD inpatients with SIgAD and perform better than the gliadin-based assays used in this study. The tests containing both tTG and gliadinic peptides are burdened by a lower specificity than the anti-tTG assays. (c) 2007 Elsevier B.V. All rights reserved.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/251734
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 68
  • ???jsp.display-item.citation.isi??? 52
social impact