The quantitative analysis of fluorescence perturbation experiments such as fluorescence recovery after photobleaching (FRAP) requires suitable analytical models to be developed. When diffusion in 31) environments is considered, the description of the initial condition produced by the perturbation (i.e., the photobleaching of a selected region in FRAP) represents a crucial aspect. Though it is widely known that bleaching profiles approximations can lead to errors in quantitative FRAP measurements, a detailed analysis of the sources and the effects of these approximations has never been conducted until now. In this study, we measured the experimental 31) bleaching distributions obtained in conventional and two-photon excitation schemes and analyzed the deviations from the ideal cases usually adopted in FRAP experiments. In addition, we considered the non-first-order effects generated by the high energy pulses usually delivered in FRAP experiments. These data have been used for finite-element simulations mimicking FRAP experiments on free diffusing molecules and compared with FRAP model curves based on the ideal bleach distributions. The results show that two-photon excitation more closely fits ideal bleaching patterns even in the event of fluorescence saturation, achieving estimations of diffusion coefficients within 20% accuracy of the correct value. (c) 2007 Optical Society of America

Role of three-dimensional bleach distribution in confocal and two-photon fluorescence recovery after photobleaching experiments.

CELLA, FRANCESCA;VICIDOMINI, GIUSEPPE;DIASPRO, ALBERTO GIOVANNI
2007-01-01

Abstract

The quantitative analysis of fluorescence perturbation experiments such as fluorescence recovery after photobleaching (FRAP) requires suitable analytical models to be developed. When diffusion in 31) environments is considered, the description of the initial condition produced by the perturbation (i.e., the photobleaching of a selected region in FRAP) represents a crucial aspect. Though it is widely known that bleaching profiles approximations can lead to errors in quantitative FRAP measurements, a detailed analysis of the sources and the effects of these approximations has never been conducted until now. In this study, we measured the experimental 31) bleaching distributions obtained in conventional and two-photon excitation schemes and analyzed the deviations from the ideal cases usually adopted in FRAP experiments. In addition, we considered the non-first-order effects generated by the high energy pulses usually delivered in FRAP experiments. These data have been used for finite-element simulations mimicking FRAP experiments on free diffusing molecules and compared with FRAP model curves based on the ideal bleach distributions. The results show that two-photon excitation more closely fits ideal bleaching patterns even in the event of fluorescence saturation, achieving estimations of diffusion coefficients within 20% accuracy of the correct value. (c) 2007 Optical Society of America
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/228882
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 33
  • ???jsp.display-item.citation.isi??? 31
social impact