Whereas the clinical diagnosis of in-stent thrombosis is straightforward, that of in-stent restenosis remains a problem, because although many patients experience chest pain after coronary stent placement, that symptom is secondary to ischemia in only a few. The use of a noninvasive technique to identify such patients for early invasive intervention versus more conservative management is thus highly desirable. Multidetector computed tomography (CT) performed with 16-section scanners recently emerged as such a technique and has overtaken modalities such as electron-beam CT and magnetic resonance imaging as an alternative to conventional angiography for the assessment of in-stent restenosis. The improved hardware design of the current 64-section CT scanners allows even better delineation of stent struts and lumen. The more reliable criterion of direct lumen visualization thus may be substituted for the presence of distal runoff, which lacks specificity for a determination of in-stent patency because of the possibility of collateral pathways. However, the capability to accurately visualize the in-stent lumen depends partly on knowledge of the causes of artifacts and how they can be compensated for with postprocessing and proper image display settings. In addition, an understanding of the major stent placement techniques used in the treatment of lesions at arterial bifurcations is helpful.

Multidetector CT for visualization of coronary stents.

MARTINOLI, CARLO;
2006-01-01

Abstract

Whereas the clinical diagnosis of in-stent thrombosis is straightforward, that of in-stent restenosis remains a problem, because although many patients experience chest pain after coronary stent placement, that symptom is secondary to ischemia in only a few. The use of a noninvasive technique to identify such patients for early invasive intervention versus more conservative management is thus highly desirable. Multidetector computed tomography (CT) performed with 16-section scanners recently emerged as such a technique and has overtaken modalities such as electron-beam CT and magnetic resonance imaging as an alternative to conventional angiography for the assessment of in-stent restenosis. The improved hardware design of the current 64-section CT scanners allows even better delineation of stent struts and lumen. The more reliable criterion of direct lumen visualization thus may be substituted for the presence of distal runoff, which lacks specificity for a determination of in-stent patency because of the possibility of collateral pathways. However, the capability to accurately visualize the in-stent lumen depends partly on knowledge of the causes of artifacts and how they can be compensated for with postprocessing and proper image display settings. In addition, an understanding of the major stent placement techniques used in the treatment of lesions at arterial bifurcations is helpful.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/226730
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 68
  • ???jsp.display-item.citation.isi??? 46
social impact