This paper outlines an experimental investigation into fundamental nucleate boiling phenomena involving finned surfaces within a narrow channel. The study delves into the effects of both channel width (2.0 mm and 0.5 mm) and the orientation of the base surface (whether horizontal or vertical). Experimental trials were conducted using a saturated pool of FC-72. Comparative analysis is presented between the experimental data obtained in the confined narrow channel and the unconfined scenario of extended surfaces. Notably, the reduction in channel width exhibits negligible influence on heat transfer to the liquid when the base surface is vertically oriented. However, in the case of a horizontally oriented base surface, a substantial reduction in heat transfer behavior is observed. Beyond a critical point, vapor stagnation within the gap is identified, marking a noteworthy phenomenon after reaching the maximum heat flux. This paper contributes valuable insights into the nuanced effects of channel confinement on boiling heat transfer, particularly in relation to the orientation of the boiling surface.

FC-72 Pool Boiling From Finned Surface Placed in a Narrow Channel: Influence of Displacement of Boiling Surface

Mario Misale;Annalisa Marchitto;Johan Augusto Bocanegra
2025-01-01

Abstract

This paper outlines an experimental investigation into fundamental nucleate boiling phenomena involving finned surfaces within a narrow channel. The study delves into the effects of both channel width (2.0 mm and 0.5 mm) and the orientation of the base surface (whether horizontal or vertical). Experimental trials were conducted using a saturated pool of FC-72. Comparative analysis is presented between the experimental data obtained in the confined narrow channel and the unconfined scenario of extended surfaces. Notably, the reduction in channel width exhibits negligible influence on heat transfer to the liquid when the base surface is vertically oriented. However, in the case of a horizontally oriented base surface, a substantial reduction in heat transfer behavior is observed. Beyond a critical point, vapor stagnation within the gap is identified, marking a noteworthy phenomenon after reaching the maximum heat flux. This paper contributes valuable insights into the nuanced effects of channel confinement on boiling heat transfer, particularly in relation to the orientation of the boiling surface.
File in questo prodotto:
File Dimensione Formato  
2025.Misale et al. FC72 pool boiling.pdf

accesso chiuso

Descrizione: Paper
Tipologia: Documento in versione editoriale
Dimensione 2.53 MB
Formato Adobe PDF
2.53 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/1250336
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact