Preventive and accurate assessment of bladder voiding dysfunctions necessitates measuring the amount of liquid encapsulated within urinary bladder walls in a non-invasive and real-time manner. The real-time monitoring of urine levels helps patients with urological disorders such as Nocturnal Enuresis (NE) by preventing the occurrence of enuresis via a prevoid stage alerting system. Although some advances have been achieved toward developing a non-invasive approach for determining the amount of accumulated urine inside the bladder, there is still a lack of an easy-to-implement technique which is suitable to embed in a wearable pre-warning device. This study aims to develop a machine-learning empowered technique to quantify to what extent an individual's bladder is filled by observing the filling-voiding pattern of a patient over a training period. In this experiment, a pulse-echo sonar element is used to generate ultrasound pulses while the probe surface is positioned perpendicular to the bladder's position. From the reflected echoes, four features which show sufficient sensitiveness and therefore could be modulated noticeably by different levels of liquid encased in the bladder, are extracted. The extracted features are then fed into a novel intelligent decision support system– known as FECOC – which is based on hybridization of fuzzy inference systems (FIS) and error correcting output codes (ECOC). The proposed scheme tends to achieve better results when examined in real case studies.

Toward Development of PreVoid Alerting System for Nocturnal Enuresis Patients: A Fuzzy-Based Approach for Determining the Level of Liquid Encased in Urinary Bladder

Rovetta, Stefano;Masulli, Francesco
2020-01-01

Abstract

Preventive and accurate assessment of bladder voiding dysfunctions necessitates measuring the amount of liquid encapsulated within urinary bladder walls in a non-invasive and real-time manner. The real-time monitoring of urine levels helps patients with urological disorders such as Nocturnal Enuresis (NE) by preventing the occurrence of enuresis via a prevoid stage alerting system. Although some advances have been achieved toward developing a non-invasive approach for determining the amount of accumulated urine inside the bladder, there is still a lack of an easy-to-implement technique which is suitable to embed in a wearable pre-warning device. This study aims to develop a machine-learning empowered technique to quantify to what extent an individual's bladder is filled by observing the filling-voiding pattern of a patient over a training period. In this experiment, a pulse-echo sonar element is used to generate ultrasound pulses while the probe surface is positioned perpendicular to the bladder's position. From the reflected echoes, four features which show sufficient sensitiveness and therefore could be modulated noticeably by different levels of liquid encased in the bladder, are extracted. The extracted features are then fed into a novel intelligent decision support system– known as FECOC – which is based on hybridization of fuzzy inference systems (FIS) and error correcting output codes (ECOC). The proposed scheme tends to achieve better results when examined in real case studies.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/1000521
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact